Electrical
Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
120 Volt, 60 Hz., AC only, 15- or 2O-amp fused electrical
supply is required. A time-delay fuse or circuit breaker is
recommended.
It is also recommended
that a separate circuit
serving only this dryer be provided.
GROUNDING
INSTRUCTIONS
• For a grounded, cord-connected
dryer:
This dryer must be grounded. In the event of malfunction or
breakdown, grounding will reduce the risk of electric shock
by providing a path of least resistance for electric current.
This dryer is equipped with a cord having an equipment-
grounding conductor and a grounding plug. The plug must
be plugged into an appropriate
outlet that is properly
installed and grounded in accordance with all local codes
and ordinances.
WARNING:
Improper connection of the equipment-
grounding conductor can result in a risk of electric shock.
Check with a qualified electrician or service representative
or personnel if you are in doubt as to whether the dryer is
properly grounded. Do not modify the plug provided with the
dryer: if it will not fit the outlet, have a proper outlet installed
by a qualified electrician.
SAVE THESE
INSTRUCTIONS
Explosion Hazard
Use a new CSA international
approved
gas supply
line.
install a shut-off valve.
Securely tighten
all gas connections.
If connected to LP, have a qualified
person make sure
gas pressure does not exceed 13" (33 cm) water
column.
Examples of a qualified
person include:
licensed
heating personnel,
authorized
gas company personnel, and
authorized
service
personnel.
Failure to do so can result in death, explosion,
or fire.
Gas Type
Natural Gas:
This dryer is equipped for use with Natural gas. It is design-
certified by CSA International for LP (propane or butane) gases
with appropriate conversion.
Your dryer must have the correct burner for the type of gas in
your home. Burner information is located on the rating plate in
the door well of your dryer. If this information
does not agree
with the type of gas available, contact your dealer or call the
phone numbers referenced on the front page of this manual.
LP gas conversion:
Conversion must be made by a qualified technician.
No attempt shall be made to convert the appliance from the gas
specified on the model/serial rating plate for use with a different
gas without consulting your gas company. For information on
ordering an LP conversion kit, please refer to the "Assistance or
Service" section of this manual. Ask for Part Number 49572.
Gas Supply Line:
Must include 1/8"NPT minimum plugged tapping accessible
for test gauge connection,
immediately upstream of the gas
connection to the dryer (see illustration).
1/2"IPS pipe is recommended.
%" approved aluminum or copper tubing is acceptable for
lengths under 20 ft (6.1 m) if local codes and gas supplier
permit.
If you are using Natural gas, do not use copper tubing.
%" flare x %" NPT adapter fitting between dryer pipe and %"
approved tubing.
Lengths over 20 ft (6.1 m) should use larger tubing and a
different size adapter fitting.
If your dryer has been converted to use LP gas, %" LP
compatible copper tubing can be used. If the total length of
the supply line is more than 20 ft (6.1 m), use larger pipe.
NOTE: Pipe-joint compounds
that resist the action of LP gas
must be used. Do not use TEFLON °t tape.