LGB 23191 Instructions De Service page 12

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

tion value 55. This also repro-
grams the loco address to the
factory pre-set value.
To reprogram the factory pre-set
function values with the 55015
(displays shows "P --") input 6, 5,
and 5 and press the right arrow
button. The display shows "P --"
again: Input 5, 5, and 5 and press
the right arrow button again.
You can program the following
registers:
Register Function
CV1
Loco address
CV2
Starting voltage
voltage for speed setting 1 - if loco starts only
at a higher speed setting, increase value.
With "Back-EMF" function active, the factory
pre-set value should not be changed.
CV3
Acceleration (1 = fast, 255 = slow)
CV4
Braking (1 = fast, 255 = slow)
Hint: When programming with the 55015 Universal Remote, the following CVs
Hint: When programming with the 55015 Universal Remote, the following CVs
are programmed by input of the number of the desired CV in CV6 and then
are programmed by input of the number of the desired CV in CV6 and then input
input of the desired function value in CV5 (see example below).
of the desired function value in CV5 (see example below).
CV5
Max. voltage
Voltage for highest speed step - if a lower top
speed is desired, decrease value.
With "Back-EMF" function active, the factory
pre-set value should not be changed.
CV5
after input of CV6
function value for CV to be programmed
CV6
CV to be programmed
CV29
Configuration
Normal direction:
4 = Analog and digital, factory-programmed
speed steps
0 = Digital only, factory-programmed
speed steps
20 = Analog and digital, user-programmed
speed steps
16 = Digital only, user-programmed speed steps
Reversed direction:
5 = Analog and digital, factory-programmed
speed steps
1 = Digital only, factory-programmed
speed steps
21 = Analog and digital, user-programmed
speed steps
17 = Digital only, user-programmed speed steps
With "Analog and digital:"
- Loco can operate on analog and digital layouts
With "Digital Only:"
- Normal operation on digital layouts.
- Operation on analog layouts not possible.
CV51
Command for front light terminal
0 = control via lighting button
1 = control via button 1 (buttons F2-F8 not used)
9 = control via button 1 (buttons F2-F8 used)
10 = control via button 2
11 = control via button 3
12 = control via button 4
13 = control via button 5
14 = control via button 6
15 = control via button 7
12
Available Factory
values
pre-set
(00..22)
[3]
(0..255)
[0]
(1..255)
[3]
(1..255)
[3]
(1..255)
[255]
[4]
[128]

Publicité

Table des Matières
loading

Table des Matières