Télécharger Imprimer la page

Beninca SA.02 KIT Livret D'instructions page 10

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 16
The delay function can be deactivated in the opening (TRAP) and closing (TRAC) phases by proceeding as
follows:
Deactivation :
1 Move Dip-switch 1 of the selector switch DP1 to OFF, all others to ON.
2 Press button P1, wait that LED PROG switches off.
3 Move the Dip-switches to the original position.
Activation :
1 Move Dip-switches 2-3-4 of the selector switch DP1 to ON, all others to OFF.
2 Press button P1, wait that LED PROG switches off.
3 Move the Dip-switches to the original position.
4
Time preset with trimmer TRAC and dip-switch 4 TRAP is thus reset.
The control unit provides testing of the power circuit good conditions (TRIAC).
The unit comes factory-adjusted with this function disabled.
This test function can be enabled or disabled as follows:
To enable the test function to check the power circuit good conditions:
1 Move Dip-switches 3-5 of the selector switch DP1 to ON, all others to OFF.
2 Press button PGM, wait that LED PROG switches off.
4 Move the Dip-switches to the original position.
5 With function activated, should a failure in the power circuit occur or in case of faulty thermal switch in the
motor, all LED's of the "Power" band will start flashing. The control unit will execute no control.
To disable the test function to check the power circuit good conditions:
1 Move Dip-switch 3 of the selector switch DP1 to ON, all others to OFF.
2 Press button PGM, wait that LED PROG switches off.
3 Move the Dip-switches to the original position.
4
With the deactivated function, even in the case of faulty power circuit, the control unit will execute the
controls.
The Dip-switches "Bypass" allow to short-circuit Normally Closed inputs which are not in use.
DIP 1
STOP Input
Off: Enabled Input
On: Disabled Input
DIP 2
FTCC Input
Off: Enabled Input
On: Disabled Input
DIP 3
FCA1 Input
Off: Enabled Input
On: Disabled Input
DIP 4
FCA2 Input
Off: Enabled Input
On: Disabled Input
DIP 5
FCC1 Input
Off: Enabled Input
On: Disabled Input
DIP 6
FCC2 Input
Off: Enabled Input
On: Disabled Input
DIP 7
FTCA Input
Off: Enabled Input
On: Disabled Input
DIP 8
Not in use
10
TRAP/TRAC deactivation
To check the good conditions of the power circuit
Functions of Dip-switch DP2 "BYPASS"

Publicité

loading