AirCon Service Center
9.3
Changing the dryer filter
1. In the basic menu, use the cursor keys or to select "Free
selection":
2. Press ENTER to confirm.
3. Skip the query requesting "CAR DATA".
4. Select "Rec/Recycling phase".
5. Set the "Pressure increase test time" to "1".
Press ENTER to confirm.
6. Deselect "Vacuum phase" using "No".
Press ENTER to confirm.
7. Deselect "Filling phase?" using "No".
Press ENTER to confirm.
8. Select "Process start?".
Press ENTER to confirm.
The service hoses will now be drained and the AirCon Service Center
basic menu will be activated. The compressor has produced a slight
internal vacuum so that the filter can be replaced with minimal refrig-
erant loss.
9. Pull out the mains plug.
10. Unscrew the screw (D) from the holder, and pull the dryer filter
straight out.