Télécharger Imprimer la page

Flotec FP4012-10 Notice D'utilisation page 6

Publicité

Les langues disponibles

Les langues disponibles

Discharge Pipe and Pressure Tank Connections
To Household
Water System
Pressure
Switch
Figure 4 - Pre-charged Tank Connections
To Household
Water System
Pump Priming
Tee and Plug
Air Volume
Pressure
or Gauge
Control Tube
Switch
Figure 5 - Standard Tank Connections
For parts or assistance, call Flotec Customer Service at 800-365-6832
Pre-Charge Tank Connection
1. Install two tees in the pump discharge port (see Figure 4). The pipe size
must be at least as large as the discharge port.
Pump Priming
Tee with Plug
2. Run a pipe or reinforced hose from one arm of the first tee to the port
or Gauge
on the pre-charged tank.
3. Connect the other end of the discharge tee to your plumbing system.
From
Well
Cap the tee with a threaded plug or a pressure gauge.
4. Check the pre-charge of air in the tank with an ordinary tire gauge. The
pre-charge should be 2 PSI less than the cut-in setting of the pump's
pressure switch. The pre-charge is measured when there is no water
pressure in the tank. Your new pump has a 30/50 PSI switch, so adjust
the tank pre-charge pressure to 28 PSI.
Congratulations! You have just completed the tank connection for your jet
pump. Please go to Page 7 for electrical hookup.
Standard Tank Connection
1. Install one tee in the pump discharge port (see Figure 5).
1864 0205 NEW SWJ
2. Run a pipe from the pump discharge port to the inlet port of your tank.
The pipe size must be at least as large as the discharge port.
3. Install a tee in the suction pipe near the pump. Install a reducer
bushing down to 1/8" NPT in the tee. Run tubing from the tee to the
port on the AVC mounted on the tank. Seal all joints with teflon tape.
See instructions provided with the tank and the AVC for details.
Congratulations! You have just completed the tank connection for your jet
pump. Please go to Page 7 for electrical hookup.
Air Volume
Control
Use only PTFE pipe thread sealant tape based joint compounds
for making all threaded connections to the pump itself. Do not
use pipe joint compounds on plastic pumps: they can react
with the plastic in pump components. Make sure that all pipe
joints in the suction pipe are air tight as well as water tight. If
the suction pipe can suck air, the pump will not be able to pull
water from the well.
From
Well
(Figure 4)
(Figure 5)
Sealing Pipe Joints
6

Publicité

loading

Ce manuel est également adapté pour:

Fp401215h-10Fp4022-10Fp4032-10