The overheating sensor detected an excessive high glass top temperature and caused it to
automatically shutdown. Heating empty cookware may cause this. Remove cookware and
let everything cool down and retry.
•
The air inlet or exhaust fan is blocked or failed and caused it to overheat. Make sure the
unit is at least 4" from walls and other objects and all vents are clear.
4.
The TEMPERATURE PROBE is not accurately keeping to the set temperature.
•
Verify the Temperature Function is selected (see Temperature Probe Section above).
•
Reattach the Probe to ensure it is securely connected.
SPECIFICATIONS
INDUCTION TYPE
POWER SOURCE
WATTAGE RANGE
TEMPERATURE RANGE
WEIGHT
DIMENSIONS
CORD LENGTH
GLASS COOKTOP DIMENSIONS
MAXIMUM WEIGHT LOAD
TEMPERATURE PROBE
SAFETY FEATURES
APPROVALS
PRODUCT WARRANTY (see warranty card included)
Aervoe Industries, Inc. warrants that this product shall be free from all defects in material and
workmanship for 1 year from date of purchase. All merchandise must be returned to the original place
of purchase to be processed according to the retailer return policy. A warranty card must be on file
with Aervoe Industries, Inc. within 30-days of purchase and proof of purchase is required to obtain
warranty performance.
8
Commercial rated/NSF approved
220V/15A, 60Hz
500 - 3000 watts (PL1-PL13)
100ºF - 450ºF (15 settings)
12.5 lbs. (5.7 kg)
16.75" x 13.2" x 3.97" (425 x 336 x 100 mm)
5 ft. (1.52m)
11.25" x 11.25" (286 x 286 mm)
75 lbs. (cookware & contents)
8" Probe. Stainless steel.
Non-suitable cookware detection
Overheat protection
Improper voltage supply detection
ETL US (conforms to UL STD 197)
ETL Sanitary approved (NSF4)
Complies with FCC Part 18