Wiring Diagram
Black
White
Fuse
Black
White
Black
Black
+Black
-White
Power 12VDC
Specifications
BTU/HR
Fuel
Inlet Pressure
Manifold Pressure
Power Input
Water Operating Pressure
Orifice (mm)
Altitudes: 0-2000ft (0~610m)
Altitudes: 2000-4500ft (610-1370m)
Product Dimensions (W x H x D)
Body Only (Model: FWH09A)
Assembly (Body and Door) Dimensions (W x H x D)
Shipping Weight
Setting Temperature Range
+12VDC
-12VDC
Ground (Black)
+24V (Red)
Feed back (White)
0~5V DC (Brown)
60,000 BTU
Propane (LP Gas)
11" WCI Min to 14" WCI Max
0.96"-7.6" WCI
12V DC < 3 Amp
7.2 PSI-65 PSI
Ø 1.1
Manifold Pressure (Pa)
Max Fan Speed
Manifold Pressure (Pa)
Max Fan Speed
125/8" (320mm) x 125/8" (321mm) x 191/8" (486.5mm)
Body with Door (FWH09EA-PS)
Body with Door (FWH41EA-PS)
Body with Door (FWH46EA-PS)
31 lbs.
95
o
F (35
To Ignition pin
To Flame sensor
To ECO thermostat
Specifications
1920
58 r/s
2360
68 r/s
161/8" x 161/8" x 191/16" (410mm x 410mm x 500.6mm)
161/8" x 181/8" x 191/16" (410mm x 460mm x 500.6mm)
181/8" x 181/8" x 191/16" (460mm x 460mm x 500.6mm)
o
C) ~ 124
o
F (51
o
C)
- 18 -
To Ground
To Remote
Black
Black
White
Outlet temp probe
White
To wind pressure switch
To water
flow sensor
Yellow
Subsection valve line
To switch on/off
proportional valve
To proportional valve
CCD-0005507 Rev: 09-13-22
Blue
Blue
Inlet temp probe
Yellow
Yellow
Black
Red
Black
Blue
Yellow
Black
Brown
Brown
Red
White
White

Publicité