and the gas controls). Remove any item present and wipe
clean the bottom of the housing.
7. Inspect the interior surface of the housing for any cracks
or corroded areas that could allow penetration of gases
into or out of the interior of the vehicle. Check especially
around the hot water, cold water, gas and electrical
connections.
NOTE: If damages found, please contact a technician to
repair or contact Furrion customer service.
8. Check that all wire connections are firmly in place and
there are no signs of chafing or cracks on the insulation.
Verify that the spark ignition cable between the Control
Board and the igniter is securely in place and not shorted
to any metal component.
9. Inspect the pressure safety valve to ensure it has not been
leaking (no water residue). See "Pressure Safety Valve
Maintenance" for further inspection. (Fig. 38)
Pressure safety
valve handle (Red)
Fig. 38
10. Inspect/clean/replace water inlet filter as necessary, see
"Filter Cleaning" section.
11. Turn on the power to the water heater and open a hot
water faucet to inspect the flame of the burner. The flame
should be of the normal bluish appearance that indicates
proper combustion. This can be accomplished by
removing the water heater door and baffle to observe the
flames by looking at the burner under the edge of the heat
exchanger. (Fig. 39)
1
Baffle
Fig. 39
12. A sealing ring is assembled on the chimney. (Fig. 40)
Inspect to make sure the seal does not have any cracks or
breaks, and that it is in good condition. Contact Furrion for
replacement.
NOTE: When installing the seal, make sure the words
"INSIDE" are facing inward.
CCD-0005507 Rev: 09-13-22
Fig. 40
Filter Cleaning
There is a filter screen on the Water Heater inlet water
line connection. The filter screen needs to be cleaned
periodically to prevent blockages from forming. Follow below
steps below to clean the filter: (Fig. 41)
1. Step
baffle.
2. Step
counterclockwise.
3. Clean the screen filter by flushing any debris
accumulated.
Fig. 41
Pressure Safety Valve Maintenance
Flame
● Never actuate the pressure relief valve while the
appliance is in operation.
● Never tamper with the pressure relief valve.
1. The unit is equipped with a water pressure safety valve.
The pressure safety valve needs to operate once each
year to ensure this safety device is effective.
2. The pressure relief valve is a safety component and must
not be removed for any reason other than replacement.
NOTE: The pressure relief valve must be replaced by a
certified ser vice technician if defective.
3. Tampering with the pressure relief valve will void the
warranty.
4. On the back of the water heater. Rotate the
pressure safety valve handle (Red) about 3~5 times
counterclockwise. (Fig. 42)
- 15 -
1
: Open the door of the Water Heater, remove the
2
: Unscrew the filter cover by hand or a proper tool
1
Baffle
WARNING
Burn or Scald Hazard
2
Filter Cover