Leak Check
Gas Leak Testing
WARNING
Fire and Explosion Hazard
● Ensure test pressures are below 40in-wc (100mbar).
● DO NOT use matches, candles or other sources of
ignition when checking for gas leaks.
● Use a gas leak detection liquid or equivalent.
● Make certain to re-test all fittings after making
adjustments to loose connections.
Failure to follow instruction may lead to serious injury,
property damage or death.
1. Verify the power switch on the water heater is in the "OFF"
position. (Fig. 16)
2. Turn on the gas supply or alternative pressure supply.
3. Check the appliance and all gas connections for gas leaks
with leak detection liquid (not provided) or an equivalent
gas leak detection method. Bubbles indicate a gas leak
that must be repaired.
4. Repair gas leaks as needed.
5. Repeat gas leak check after any adjustments to loose
connections.
NOTE: After leak checking, make sure the gas supply
pressure corresponds to the operating pressure of the
appliance 11~14in-wc (27.4~34.9mbar).
Water Leak Testing
IMPORTANT: DO NOT exceed 116PSI when pressure leak
testing the system with compressed air.
1. Verify the power switch on the water heater is in the "OFF"
position .(Fig. 16)
2. Turn on the water supply to the unit
3. Open water faucets to fill the system with water. Close the
faucets when the water is flowing smoothly and all air is
removed from the lines.
4. Check all connections for water leaks by eye and touch.
5. Repair leaks as needed.
6. Repeat check for water leaks and take any necessary
steps to repair the leaks at all water connections.
Operation
Controller Operation
Before normal operation of the appliance, perform a basic
functional test check out each time the RV and water system
is setup for use. Refer to "Functional Test" of this manual
for instruction. After the Functional test is completed, the
appliance can be operated from the wall controller which
includes the Power switch. The control switch can be used
for in living "ON/OFF" function.
Functional Test
Fire or Explosion Hazard
● Ensure all necessary system leak tests are complete
before performing any functional test
Failure to follow instructions could lead to serious injury,
property damage or death.
1. Verify the power switch is in the "OFF" position.
(Fig. 16)
2. Confirm that there is a "steady" water flow (not pulsating)
and no air in the system. If pulsating have the water pump
settings adjusted.
3. Make certain all valves that can mix cold and hot water are
all shut.
NOTE: Outside faucets with detachable spigots and
shower heads with flow interrupters can bleed hot water
into the cold side if the valves are not closed properly. This
will hinder the performance of the water heater.
4. Turn the power switch to the "ON" position (Fig. 16) and
verify the wall controller is illuminated. If the wall controller
is not illuminated, press
illuminate. (Fig. 35) The wall controller display will show
the Hot Water temperature setting.
NOTE: The default factory setting is 115
UP
Fig. 35
DOWN
5. Turn on the gas supply.
6. Open a hot water faucet and verify that the unit ignites
and supplies hot water at the faucet.
7. The wall controller display will show the current
temperature settings.
NOTE: If any error codes or performance concerns, refer
to the trouble shooting section of this manual.
This completes the installation of the Furrion water
heater.
1. Touch button
to turn the power
ON/OFF
ON/OFF. Furrion logo
on the panel will be illuminated and
display the current temperature
setting.
NOTE: The micro processor is
always on. It draws approximately
0.25 AMPs, but is advisable to turn
off when not in use.
2. Touch button marked "°F/°C"
- 12 -
WARNING
button on the wall controller to
F or 46
o
POWER
O
F
O
C
FLAME
ON/OFF
F /
C
o
o
POWER
UP
DOWN
to transform the
CCD-0005507 Rev: 09-13-22
C.
o
O
F
O
C
FLAME
ON/OFF
o
F /
o
C

Publicité

loading