G
B
resume work at the set speed.
TECHNICAL SPECIFICATIONS
- Humidity
- Power voltage
- Frequency
- Maximum board absorption
- Interruptions in electricity supply
- Maximum load of open gate output
- Blinking unit maximum output load
- Current available for photocells and accessories 400mA 24Vdc
- Current available on radio connector
- ALL THE PUSH BUTTONS, INPUTS AND COMMANDS CONNECTED TO THE CONTROL
BOARD MUST BE CLEAN CONTACT.
TECHNICAL RADIO SPECIFICATIONS (Only L1-CRX)
- Reception frequency
- Impedance
- Sensitivity
- Excitation time
- De-excitation time
- Codes in store
- All the inputs must be used as clean contacts because the power supply is generated
internally (safe voltage) in the card and it is set in a way to guarantee the use of the double
insulation and reinforced in relation to parts with hazardous voltage.
- Any external circuits connected to the outputs of the control board, must be carried out to
make sure the double or reinforced insulation is used in relation to parts with hazardous
voltage.
- All the inputs are run by a programmed integrated circuit which carries out a self-check at
the beginning of each operation.
After having carried out the various connections and having supplied voltage, all the LEDS
are switched off.
The motor opens and closes, but it has no strength and moves slowly.
The gate opens but does not close after the time set.
The gate does not open or close by activating the various START, RADIO, OPEN and CLOSE
buttons.
Motor with encoder (DIP 8 at On) enabled. The gate opens and closes only for brief intervals. Check encoder connection and eventually replace.
By activating the START, OPEN or CLOSE button the gate does not move.
The slowing phase is not performed.
< 95% without condensation
230V~ ±10% (120V/60Hz upon
request)
50/60Hz
30mA
100ms
3 W (equal to 1 3W bulb or to 5 LEDs
connected in series through a resistor
of from 2.2 Kohm)
40W with resistive load
200mA 24Vdc
433,92MHz
52 Ω
>2.24µV
300ms
300ms
N° 1000 total
FAULT
MAINTENANCE CHECK
N.B.: During this check the safety functions Edges, Photocells, Stop button and Impact
detection are NOT active.
1 - Set DIP 1 to ON => LED DL1 starts to flash.
2 - Press and hold the PROG button (the command is hold-to-run, open-stop-close-stop-
open-etc ...) => The gate starts at high speed and then slow down until the limit switch
is reached.
3 - At the end, put DIP 1 back to the OFF position. The DL1 LED turn off signaling the exit
from the check.
If the motor does not work during this check, check the connections and its capacitor.
If the motor is working properly, check the safety devices.
TROUBLE SHOOTING
After having carried out all connections, by carefully following the layout and having
positioned the gate in intermediate position, check the correct ignition of red LEDS DL6, DL7,
DL8, DL9 and DL10.
In case of no ignition of the LEDS, always with gate in intermediate position, check the
following and replace any faulty components.
DL6
OFF
the jump between COM A+ and STOP).
DL7 or DL8
OFF
out jumper between COM A+ and PHOTO 1/PHOTO 2)
DL9 or DL10
OFF
out jumper between COM A+ and EDGE 1/EDGE 2)
LED DL13 (BLUE)
ON
smartphone check the card functions as the dips/trimmers status may not be true.
On the board there are resettable fuses which intervene in the event of a short circuit,
interrupting the output assigned to them.
In the event of troubleshooting, it is advisable to disconnect all the removable
connectors and insert them one at a time in order to more easily identify the cause
of the fault.
On the board there are resettable fuses which intervene in the event of a short circuit,
interrupting the output assigned to them.
In the event of troubleshooting, it is advisable to disconnect all the removable
connectors and insert them one at a time in order to more easily identify the cause
of the fault.
Check the integrity of fuse F1.
In case of interrupted fuse use only of adequate value
F1 = T 5A Fuse for motor protection
Check trimmers TORQUE and LOW-SPEED adjustment.
Make sure that the TCA trimmer is activated with LED DL11 ON.
B.I.O. contact always on / green led on => check the status of the clock connected to B.I.O.
input.
Photocells Auto-test failed => check the connections between the control panel and the
photocells.
Faulty safety edge contact. Faulty photocells contact with DIP 4 OFF. => Fix or replace the
faulty contact.
Photocells Auto-test failed => check the connections between the control panel and the
photocells.
START, OPEN or CLOSE command always active.
Check and replace any buttons or micro-switches of the selector switch.
Ensure that DIP 9 is in ON position (Slowdown enabled).
Perform the programming times procedure with DIP 2.
Check LOW SPEED trimmer adjustment.
26
Stop button malfunction (if Stop is not connected, perform
Faulty photocells (In case the edge is not connected, carry
Faulty safety edge (In case the edge is not connected, carry
Some functions are enabled via smartphone, so via
SOLUTION