- English -
Storage/Winterization
● Put the unit out of operation at water temperatures below 46 °F (8 °C) or, at the latest, when freezing temperatures are
to be expected.
● Thoroughly clean the unit, check for damage.
● Ensure that the storage place is inaccessible to children.
Wear parts
The impeller unit is a wear part and is excluded from the warranty.
Disposal
Do not dispose of this unit with domestic waste! Disable the unit beforehand by cutting off the cables. Further
information about the recycling of this product can be obtained from your local municipal authority.
Troubleshooting
Issue
Cause
The unit is not
Power supply not connected
performing its
suction function
Impeller blocked, shaft broken
Fountain or spitter clogged
Pump is not completely submerged
Insufficient flow
Flow control closed too far
Screen clogged
Tubing blocked
Tubing kinked
Excessive flow loss in the
tubing due to friction
Pump overload. The flow is
automatically stopped to protect
the pump.
Pump is not completely submerged
Impeller worn
Unit switches
Excessive soiled water
off after a short
running period
Impeller blocked, shaft broken
Water temperature too high
Solution
Connect pump power supply, check the supply lines to make sure
the voltage is correct
Remove the front cover, and impeller cover to expose the
impeller. Turn the impeller to ensure that it is not broken or
jammed by debris. Also check to make sure that the ceramic
shaft or bearings are not broken.
Check for kinks or obstructions in tubing or spitter.
Completely submerge pump in the water
Adjust flow control
Clean
Clean or replace tubing
Eliminate kink, replace tubing if it is damaged
○ Reduce tubing length to reduce frictional loss
○ Select larger adapter and hose diameter.
○ Clean the pump housing and impeller assembly
○ Reduce the ambient temperature (e.g. ensure that the specified
water temperature is adhered to, avoid direct sunlight)
Completely submerge pump in the water
Replace impeller assembly
Clean impeller housing, bearing and impeller assembly on pump
and clean fountain water
Remove the front cover, and impeller cover to expose the
impeller. Turn the impeller to ensure that it is not broken or
jammed by debris. Also check to make sure that the ceramic
shaft or bearings are not broken.
Maximum water temperature: +95°F (+35 °C)
6