English
5.5
GWP value / CO
equivalent
2
5.6
Refrigeration circuit hermetically sealed
5.7
Lubricant / total filling quantity
5.8
Volume of heating water in device
6
Electrical connection
6.1
Supply voltage / fusing / RCD type
6.2
Control voltage / fusing by WPM
6.3
Degree of protection according to EN 60529
6.4
Starting current limiter
6.5
Rotary field monitoring
6.6
Starting current with soft starter
6.7
Nominal power consumption A2/W35 /
max. power consumption
Nominal current A2 /W35 / cos
6.8
6.9
Power consumption of compressor protection
(per compressor)
6.10 Power consumption of fan
7
Complies with the European safety regulations
8
Additional model features
8.1
Type of defrosting
8.2
Frost protection, condensate tray /
Water in device protected against freezing
8.3
Maximum operating pressure (heat source/heat sink)
8.4
Energy efficiency class / energy efficiency (low temperature)
8.5
Energy efficiency class / energy efficiency (mean temperature)
4
9
Heat output COP
9.1
Heat output / COP
10 Cooling capacity / COP
10.1 Cooling capacity / COP
1. For air temperatures between -22°C and -5°C, flow temperature increasing from 45? to 60?.
2. operation with 2 compressors
3. Operation with 1 compressor
4. These data indicate the size and capacity of the system according to EN 14511. For an analysis of the economic and energy efficiency of the system, other parameters, in par-
ticular the defrosting capacity and regulation, should also be taken into consideration. These figures are only achieved with clean heat exchangers. Instructions for care, com-
missioning and operation can be found in the relevant sections of the installation and operation instructions. The specified values have the following meaning, e.g. A7/W35:
outside air temperature 7 °C and heating water flow temperature 35 °C.
5. Standard nominal flow only possible with an electronically controlled circulating pump with actuation via heat pump manager.
6. The heat output and COP is reduced by approx. 5 % in lower operation
7. When the optional weather protection hood (accessory) is used. the sound pressure level in outlet direction is reduced by 3 dB(A).
8. The specified sound pressure level represents the free sound area level. The measured value can deviate by up to 16 dB(A). depending on the installation location.
9. See CE declaration of conformity
10.The heat circulating pump and the heat pump manager must always be ready for operation.
11.The coefficient of performance (COP) in partial load operation can be increased by selecting "energy-optimised heating operation" (natural defrosting)
12.The maximum sound power level under full load can increase by up to 5 dB(A).
EN-12
4
10
Performance level
at A-7 / W35
at A2 / W35
at A7 / W35
at A7 / W45
at A7 / W55
at A10 / W35
4 12
Performance level
at A27 / W18
at A27 / W9
at A27 / W7
at A35 / W18
at A35 / W9
2
at A35 / W7
452168.66.01a · FD 0102
--- / t
2088 / 8
yes
type/litres
Polyolester (POE)/1.2
Litres
2.6
3~/N/PE 400 V (50 Hz) /
C10 A / A
1~/N/PE 230 V (50 Hz) /
4 AT
IP 24
Soft starter
Yes
A
21
1.7 / 3.3
kW
A / ---
3.1 / 0.8
70 / thermostatically
W
controlled
W
< 150
9
Reverse circulation
Yes
bar
3.0
A++ / 172 %
A++ / 125 %
EN 14511
1
kW / ---
5.5 / 3.2
kW / ---
7.2 / 4.2
kW / ---
8.4 / 4.8
kW / ---
8.2 / 3.7
kW / ---
8.0 / 3.1
kW / ---
8.9 / 5.1
EN 14511
1
kW / ---
7.9 / 4.3
kW / ---
kW / ---
5.4 / 3.0
kW / ---
7.0 / 3.2
kW / ---
4.9 / 2.3
kW / ---
LA 9S-TU(R) - LA 18S-TU(R)
2088 / 9
yes
Polyolester (POE)/1.2
3.8
3~/N/PE 400 V (50 Hz) /
C10 A / A
1~/N/PE 230 V (50 Hz) /
4 AT
IP 24
Soft starter
Yes
19
2.38 / 4.0
4.3 / 0.8
70 / thermostatically
controlled
< 200
9
Reverse circulation
Yes
3.0
A++ / 167 %
A++ / 125 %
EN 14511
2
1
2
---
7.3 / 3.1
---
9.5 / 4.0
---
---
11
(4.2)
---
11.3 / 4.7
---
---
10.8 / 3.8
---
---
10.0 / 3.0
---
---
12.0 / 5.0
---
EN 14511
2
1
2
---
8.6 / 3.6
---
---
---
---
6.3 / 2.6
---
---
7.9 / 2.8
---
---
---
---
5.3 / 2.0
---
www.glendimplex.de
2088 / 12
yes
Polyolester (POE)/1.2
3.8
3~/N/PE 400 V (50 Hz) /
C13 A / B
1~/N/PE 230 V (50 Hz) /
4 AT
IP 24
Soft starter
Yes
21
3.24 / 6.8
5.9 / 0.8
70 / thermostatically
controlled
< 250
9
Reverse circulation
Yes
3.0
A++ / 179 %
A++ / 130 %
EN 14511
1
2
5.6 / 3.2
10.6 / 3.2
12.3 / 3.8
7.3 / 4.2
11
(3.9)
8.4 / 4.8
8.1 / 3.8
7.7 / 3.1
8.8 / 5.2
EN 14511
1
2
8.2 / 4.4
15.4 / 3.7
12.7 / 3.2
6.0 / 3.3
6.7 / 3.1
14.0 / 3.0
12.2 / 2.6
5.2 / 2.5