Télécharger Imprimer la page

Continental Fireplaces X 70 Serie Manuel D'installation Et D'opération page 31

Publicité

Les langues disponibles

Les langues disponibles

8.12 blower placement
WARNING
!
• Risk of fire and electrical shock!
• Turn off the gas and electrical power before servicing this appliance.
• Use only Wolf Steel approved optional accessories and replacement parts with this appliance. Using
non-listed accessories (blowers, doors, louvres, trims, gas components, venting components, etc.) could
result in a safety hazard and will void the warranty and certification.
• Ensure that the fan's power cord is not in contact with any surface of the appliance to prevent electrical
shock or fire damage. Do not run the power cord beneath the appliance.
• The wire harness provided in the blower kit is a universal harness. When installed, ensure that any excess
wire is contained, prevent it from making contact with moving or hot objects.
This appliance comes equipped with a blower, a heat sensor, variable on/off speed control and a power cord.
The blower is thermally activated, so when it is turned on, it
will automatically start approximately 15 minutes after lighting
the appliance and will run for approximately 30 minutes after
the appliance has been turned off. Use of the fan increases the
output of heat. Air, drawn in through the lower louvre access
door, is driven up the back of the firebox, and exhausted as hot
air between the upper louvres.
A.
Open the lower control area.
B.
Remove the control panel (3 screws).
C.
Unplug the blower from the junction box or turn off the
power to the appliance if hard wired.
D.
Undo the fastener at the left side of the blower
mounting plate. The blower should now slide to the
left, away from the mounting tab.
Finally, disconnect the slip-on connectors at the motor
E.
of the blower.
Drywall dust will penetrate into the blower bearings, causing irreparable damage. Care must be taken to prevent
drywall dust from coming into contact with the blower or its compartment. Any damage resulting from this condi-
tion is not covered by the warranty policy.
SPECIFIC BLOWER INSTALLATION
INSTRUCTIONS MUST BE ADDED HERE.
THIS TEMPLATE MUST BE USED WITH ANY
APPLIANCE THAT OFFERS THE BLOWER AS
AN OPTION OR COMES STANDARD WITH THE
APPLIANCE... AS PER THE STANDARD.
G
B
VARIABLE SPEED SWITCH
W
BLOWER REPLACEMENT
B
A
35.1
operation
EN
HEAT SENSOR
FAN
C
31
W415-1797 / A / 05.07.18

Publicité

loading

Ce manuel est également adapté pour:

Cx70-1Cx70nte-1Cx70pte-1