Guidelines for ventilation
This appliance may only be set up in a sufficiently ventilated
room and according to the applicable regulations and
ventilation requirements.
Please note that the air volume required for combustion must
not be below 2 m³ per kW of power (see kW total power on the
rating plate).
Electrical connection
Only a licensed expert may connect the appliance. The
appliance must be installed according to the most recent IEE
regulations (Institute of Electrical Engineers). The appliance
may be damaged if incorrectly connected.
Make sure the voltage of the power supply corresponds to the
specified value on the rating plate. The rating plate is on the
side of the oven door.
Ensure that the power supply is properly earthed and that the
fuse and the wiring and piping system in the building can
withstand the load from the appliance.
It is recommended that you configure the circuit for the
appliance to 16 A.
When you route the cable, make sure that:
the cable is not trapped or squashed.
■
the cable, for example, does not come into contact with
■
sharp edges or cutting edges.
the cable does not come into contact with parts that can
■
reach temperatures of more than 50 °C above room
temperature.
Connecting the appliance to the power supply
The appliance corresponds to protection class 1 and may only
be operated with a protective earth connection.
The appliance must be disconnected from the power supply for
all installation work.
Gas connection
The appliance must be connected in accordance with the
currently applicable regulations. Before installing the appliance,
check if the local conditions (type of gas and pressure) are
compatible with the appliance settings. The conditions for
setting the appliance can be found on the rating plate.
Connection to the gas lines and seal fitting must be carried out
professionally according to the currently applicable standards.
Gas connection on the appliance
The gas connection (ISO 228 G1/2) is located at the rear left of
the appliance. The following connections are provided with the
appliance:
Adapter piece EN ISO 228 G1/2 - EN 10226 R1/2
(with flat seal)
Hose connection EN ISO 228 G1/2 - LPG (with flat
seal)
For appliances with a total power of up to 11 kW, it is sufficient
if the room where it is to be installed has a capacity of more
than 20 m³ and at least one door to the outside or a window
that can be opened.
Note: In some countries, there are differing requirements
concerning the minimum capacity. Your after-sales service
department will provide you with information about this.
The appliance must only be connected to the power supply with
the power cable provided.
Contact protection must be ensured by the installation.
Only a licensed expert may connect the appliance. He is
subject to the regulations of the local electricity provider.
Power cable without a plug without earthing contact
An all-pole isolating switch with at least a 3 mm contact gap
must be fitted in the installation. Identify the phase and neutral
conductors in the socket. The appliance may be damaged if
incorrectly connected.
Connection to nominal voltage 220-240 V. Connect the wires of
the mains power cord according to the colour coding: green/
yellow = PE conductor
, blue = (zero) neutral conductor,
<
brown = phase (external conductor).
GB, IE, NZ, IL, DK and AU
Fixed connection only.
Power cable with a plug with earthing contact
The appliance can also be connected using the enclosed plug
with earthing contact to a properly installed earthed socket. The
socket must be accessible after installation. If this is not the
case, an all-pole isolating switch with a contact gap of at least
3 mm must be included in the installation.
Default setting of the burners
The burners are set up for G30 liquefied gas (29 mbar) on
delivery. A nozzle set for G20 natural gas (20 mbar) is supplied
with the appliance.
15