Configuring the Heat Pump Heating System
System-specific parameters
If the heat pump is operated with an additional
heat exchanger, is parallel operation of heating
and domestic hot water resulting in higher hot
water temperatures being reached desirable?
Sets the desired hot water temperature which is
to be reached in parallel heating – hot water
operation.
Is parallel operation of cooling and domestic
hot water possible due to the hydraulic isolation
of the cooling circuit and the hot water circuit?
Sets the desired hot water temperature
Sets the time programs for hot water blocks
Sets the times in which DHW preparation is
blocked
For each day of the week, it is possible to select
whether Time1, Time2, no time or both times
are to be active when the temperature is
lowered. Operations to lower the temperature
that exceed a weekday are activated or
deactivated at the end of each day accordingly.
To carry out a thermal disinfection, the DHW is
heated up once to the desired temperature.
The heating period is terminated automatically
when the set temperature is reached or after 4
hours at the latest.
Sets the start time for the thermal disinfection
Sets the desired hot water temperature which is
to be reached during thermal disinfection
For each day of the week, it is possible to select
whether thermal disinfection is desired at the
set start time.
By setting Reset to "Yes", the maximum
calculated hot water temperatures in HP
operation are reset to a value of 65 °C. The
setting is automatically reset to "No".
Sets the preparation of swimming pool water
Sets whether swimming pool water preparation
is carried out with 1 or 2 compressors
Sets the time programs for blocking swimming
pool water preparation
Setting range
Display
No
Additional heat
exchanger
Yes
Domestic hot water
Sensors
10° C
Parallel heat - DHW
... 45° C ...
Additional HE
80° C
Domestic hot water
Sensors
No
Domestic hot water
Yes
Sensors
Passive cooling
function
30° C
Domestic hot water
... 45° C ...
Sensors
85° C
Domestic hot water
00:00
Domestic hot water
...
23:59
N
Heating circuit 3
T1
T2
Y
Domestic hot water
Sensors
Bivalent or flange
heater
00:00
Domestic hot water
...
Sensors
23:59
Bivalent or flange
heater
60° C
Domestic hot water
... 65° C...
Sensors
85° C
Bivalent or flange
heater
N
Domestic hot water
Y
Sensors
Bivalent or flange
heater
No
Domestic hot water
Yes
Sensors
Swimming pool
1 Compressors
Swimming pool
2 Compressors
2 Compressors
Nonreversible HP
Swimming pool
6.1
EN-15