Electrical Installations for the Heat Pump
E3** Defrost end pressure switch
E9
Electric immersion heater hot water
E10* 2nd heat generator (boiler or elect. heating element)
selectable via controller)
F2
Load fuse for plug-in terminals J12 and J13 5 x 20 / 4.0 A
slow-acting
F3
Load fuse for plug-in terminals J15 to J18 5 x 20 / 4.0 A
slow-acting
F4** High-pressure switch
F5** Low-pressure switch
F6** Flow temp. limit thermostat
H5* Remote fault indicator lamp
J1
Control unit power supply connection
(24 V AC / 50 Hz)
J2
Connection for hot water sensor, return flow sensor and
external sensor
J3
Input for HP code and flow sensor via
control line plug connector X8
J4
0-10 V DC output for controlling the frequency
converter, remote fault indicator, and swimming pool
circulating pump
J5
Connection for hot water thermostat, swimming pool
thermostat and utility block functions
J6
Connection for the heating circuit 2 sensor and defrost end
sensor
J7
Connection for "low-pressure brine" alarm message
J8
230 V AC input and outputs for controlling the HP
Control line plug connector X11
J9
Socket not used
J10
Socket for connecting the remote control (6-pole)
J11
Connection not used
J12 to
J18
230 V AC - outputs for controlling the system
components (pump, mixer, heating element, solenoid
valve, boiler)
K9
Coupling relay 230 V/24 V for defrost end or
flow temperature limit
K11* Electron. relay for remote fault indicator
K12* Electron. relay for swimming pool water circulating pump
K20* Contactor for heat exchanger 2
K21* Contactor for electric immersion heater hot water
K22* Utility blocking contactor (EBC)
K23* Auxiliary relay for SPR
K28* External switching to "cooling" operation
Fig. 4.2:
Circuit diagram of the wall-mounted heat pump manager
M1** Compressor 1
M2** Ventilator - only for air-to-water heat pumps
M3** Compressor 2 - only for systems with two compressors
M11* Heat source primary pump (brine or well pump)
M13* Heat circulating pump
M15* Heat circulating pump for heating circuit 2/3
M16* Auxiliary circulating pump
M18* Hot water circulating pump
M19* Swimming pool water circulating pump
M21* Mixer for main circuit or heating circuit 3
M22* Mixer for heating circuit 2
N1
Control unit
N6* Cooling controller
N10* Remote control (for WPM 2007 R already used
by control panel N14)
N11* Relay module
R1
External wall sensor
R2
Return flow sensor
R3* Hot water sensor
R5
Sensor for heating circuit 2
R9
Flow sensor
R12 Defrost end sensor
R13 Sensor for heating circuit 3 / renewable sensor
T1
230 / 24 V AC / 28 VA safety transformer
W1
Control line, 15-pole
W1-# Core number of cable W1
W1-#8 must always be connected!
X1
Terminal strip - supply connection, N and PE distribution
board
X2
24 V AC distribution board terminal
X3
Distribution board terminal - ground
X4
Plug connector terminal
X8
Control line plug connector (extra-low voltage)
X11 230 V AC control line plug connector
Abbreviations:
MA
Mixer "OPEN"
MZ
Mixer "CLOSED"
*)
Components must be supplied by the customer
**
Components are in the heat pump
–––– Wired ready for use
- - - - To be connected by the customer as required
4
EN-7