ABNORMALITIES
The appliance restarts
numerous times even wi-
thout a utensil.
The utensil does not emit
air.
Fall of pressure in the air
tank.
Safety valve intervention. Pressure switch fault.
Ai r loss f rom the pressure
switch when appliance
is off.
The appliance vibrates
and/or emits lots of noise.
Frequent start-ups and
low performance.
7
9
MOD. CS 240/03
Rev. 00 - 12/2013 - Cod. CM31710 - Instruction manual
CAUSE
Leakages from the air pipe,
utensil or pneumatic sy-
stem.
The tank is not pressurised. • Switch on the appliance and wait until the tank fills che-
Incorrect regulation of the
outlet pressure.
The utensil is damaged.
Leakages in the air pipe,
utensil or the pneumatic
system.
Unclean or worn return
valve.
Mechanical fault.
Unclean air filters.
MOD. CS 240/5+5
SOLUTION
• Check that the pneumatic system is not damaged.
• Check that the air pipe and utensils are intact as well as
the connections.
cking the pressure of the relevant gauge.
• Check that the value displayed on the outlet pressure
gauge (7) is greater than 0 (zero) bar.
• Check that the utensil is intact and effective.
• Check that the pneumatic system is not damaged.
• Check that the air pipe and utensil are not damaged.
• Check that the appliance-air pipe and air pipe-utensil
connections are correct.
• Check that the condensate pump is securely closed (9).
• Contact an authorised Supplier.
• Contact an authorised Supplier.
• Contact an authorised Supplier.
• Carry out filter cleaning (see Paragraph 31).