Installation
2
Installation
IMPORTANT
Bubble formation and cavitation in the medium can cause sensor malfunction and
must be avoided. Cavitation is strongly dependent on the medium, flow rate and
medium temperature. SIKA recommends the following minimum system pres-
sures.
The flow sensor can always be installed anywhere along the pipeline. However, straight
sections of piping are preferable.
Running empty
possible
- 16 -
Recommended minimum system pressure
DN10
DN15
2 bar
1 bar
Bubble-formation and
running empty possible
Contamination
possible
DN20
DN25
1 bar
1 bar
Contamination
possible
© SIKA • Ea7900_VTY • 09/2023
VTY