• If the hose and regulator are not included by the manufacturer, then only hoses and regulators which meet national and regional codes
are to be used.
• Do not connect the appliance to a permanent gas installation.
• Ensure that the hose does not come into contact with grease, other hot drippings, or any hot surfaces on the appliance.
• Check hose regularily. In the case of rips, melting or wear, replace hose before using the appliance.
• The recommended hose length is 0.5m. The hose must not be longer than 1.5m.
• Ensure that the hose is twist and kink free when installed.
• Replace the hose before expiry date printed on the hose.
The following table lists input values for the appliance.
BURNER
MAIN
BACK
SIDE
Certified Gases / Pressures - Check rating plate to ensure that it corresponds with following list.
Gas Category
Orifice Sizes (see above)
Gases / Pressures
Countries
The regulators for both butane and propane must have a rating of at least 1200 g/h. Do not tamper with or modify regulator. Use only
regulators which supply the pressure listed in the table above.
LEAK TESTING INSTRUCTIONS
LEAK TESTING: This must be done before initial use, annually and whenever any gas components are replaced or serviced. No smoking
while performing this test, and remove all sources of ignition. See Leak Testing Diagram for areas to check.
1. Turn all burners controls to off. Turn supply valve on.
2. Brush a half and half solution of liquid soap and water onto all joints and connections of the regulator, hose, manifolds and valves.
3. Bubbles will indicate a gas leak. Either tighten the loose joint or replace the part with one recommended by the dealer.
4. If the leak cannot be stopped, shut off the gas supply, disconnect it and have the barbecue inspected by your gas supplier or dealer. Do
not use the appliance until the leak has been corrected.
5. Turn off gas supply.
GAS HOSE
REGULATOR
ORIFICE SIZE
HEAT INPUT
I
II
(TOTAL)
#60
1.45mm
13.2 kW
#58
1.5mm
4.1 kW
#69
#57
2.3 kW
I
3B/P(30)
I
Butane 30mbar
Propane 30mbar
CZ, DK, FI, GR,
NL, NO, SE
DO NOT USE A FLAME TO LEAK TEST.
GAS USAGE (TOTAL)
PROPANE
944 g/h
293 g/h
164 g/h
I
3+(28-30/37)
I
Butane 28-30mbar
Natural Gas 20mbar
Propane 37mbar
BE, CH, CZ, ES,
AT, CH, CZ, DK,
FR, GB, IE, IT,
ES, FI, GB, GR,
PT
IE, IT, NO, PT, SE
BUTANE
960 g/h
298 g/h
167 g/h
I
I
2H(20)
2E(20)
II
II
Natural Gas 20mbar
DE, LU