Installation
Use as opening detector:
The detector may be installed in either of the two possible vertical positions.
The distance between the device and the magnet must not be more than 15 mm when the door is closed.
Avoid installation on metal surfaces, if possible.
Install the device as high as possible.
Use as shock/vibration detector:
The device can be installed on perfectly flat concrete or wood surfaces or on window and door frames.
When installed on windows or doors, it can also be used as an opening detector. IMPORTANT NOTE: Detection on
multilayer or mesh glass is not guaranteed because the vibrations are attenuated by the materials.
Use the following table as a reference for the selection of materials and detection parameters.
Thickness
Material
Positioning
Detection type
Detection
Low
diameter for
Medium
different
High
sensitivities
9
Door
Coverage area:
up to 1,5 m
Window glass
> 5mm
Normal or tempered
Mobile window frame
Single pulse
2m
3m
4m
Window
Coverage area:
up to 2 m
Door
<40mm
Wood/steel
Door frame
On the wall near the detection point
Multiple pulse / sum of vibrations
detection
1m
2m
3m
Window
Coverage
area: up to
2 m on
each
window
Masonry
-
Cement/concrete
0.5m
1.5m
2m