SAFE T Y N OT ES
W A R N I N G :
failure, propert y damage, and personal
injury, do the following:
This product should be installed by a licensed
professional plumber.
This product is for use with drinking water
only.
Install this faucet in an accessible area. Keep
away from external heat sources. The hoses
should not be allowed to rub against other
items under the sink, such as a trash bin.
The hot and cold supply hoses are for use
with ⅜ stops. If your stops are a different
size, install new ones. Using anything other
than ⅜ stops may result in product failure
and property damage.
The hoses on this faucet must not come into
contact with detergents or other materials
containing chlorine bleach, lye, hydrochloric
acid, formic acid, acetic acid, or other harsh
chemicals as they can damage the hose. Do
not store such materials under the sink where
this faucet is installed.
Inspect the hoses for leaks or corrosion imme-
diately after installation and every six months
thereafter. Replace the hose if signs of leaks
or corrosion are detected.
Refer to the Cleaning Recommendations on
page 15 when selecting a cleaning agent
for this product. Do not use cleaning products
containing chlorine bleach, lye, hydrochloric
acid, formic acid, acetic acid, or abrasives.
Failure to follow these instructions may result
in product failure and property damage, and
may void the warranty.
2
To avoid the risk of product
E N G L I S H
INSTALL ATION CONSIDERATIONS
⁄ Read over these instructions thoroughly before begin-
ning installation. Make sure that you have all tools
and supplies needed to complete the installation.
⁄
MODEL 36121XX1 ONLY:
perature from a bidet fitting shall be limited to a maxi-
mum temperature of 110ºF (43ºC) by a water tem-
perature limiting device conforming to ASSE 1070.
⁄ 36110XX1, 36121XX1 ONLY: The drain is suitable
for most, but not all, lavatory sinks sold in the United
States and Canada.This drain is intended for use in
a sink with an overflow. If your sink does not have
an overflow, or if this drain is too small for the hole
in your sink, please refer to the instructions included
with the sink. Some sinks include special drain instal-
lation instructions and/or parts. Others require the
use of a specialty drain. Hansgrohe is not respnsible
for the cost of a specialty drain.
⁄ Models 36113XX1 and 36111XX1 include neither
drain nor pull rod.
⁄ Keep this booklet and the receipt (or other proof of
date and place of purchase) for this product in a
safe place. The receipt is required should it be neces-
sary to request warranty parts.
T EC HN I C A L IN FO RM AT ION
Water pressure
Recommended
Maximum
Hot water temp.
Recommended
Maximum
Max. flow rate
Hole size in mounting surface
Max. depth of mounting surface
* Please know and follow all applicable local plumbing
codes when setting the temperature on the water heater.
The discharge water tem-
15 - 75 PSI (0.1 - 0.5 MPa)
145 PSI (1 MPa)
120°-140° F (48° - 60° C)*
158°F (70° C)*
1.2 GPM (4.5 L/min)
1⅜" (36 mm)
1⅜" (35 mm)