en - Installation notes
14
must be provided on site. Switches with a minimum contact gap
greater than 3 mm are suitable disconnectors. These include circuit
breakers (MCB), fuses and contactors (VDE 0660) (IEC/EN 60947)
If the mains supply cannot be permanently disconnected, the isolation
device (including plug and socket) must be safeguarded against being
switched on either unintentionally or without authorisation.
The tumble dryer must not be connected to devices such as timers
which would switch it off automatically.
If local regulations require that a residual current device (RCD) is in-
stalled, a type B residual current device (sensitive to universal cur-
rent) must be used.
Steam connection
The steam connection must only be carried out by a registered install-
ation technician. The information from the data plate, the wiring dia-
gram and the documentation accompanying the appliance must be
noted and complied with when connecting steam-heated Miele appli-
ances.
Condensate connection
The condensate separator must be installed so that when the system
is not operating, the heater bank is completely emptied. This means
that no condensate may remain in the heater bank. The installation of
an inverted bucket condensate trap is recommended.
Air intake/exhaust air
The tumble dryer may only be operated when the ducting has been
connected properly and the room is sufficiently ventilated.
Accessory parts may only be fitted when expressly approved by
Miele. If other parts are used, warranty, performance and product liab-
ility claims will be invalidated.