EN Dometic HiPro Alpha, Evolution
NOTE Condensation moisture on glass doors
When the ambient humidity is above 65 % in 77 °F (25 °C) ambient temperature, moisture will condense
on the glass door.
Clean the minibar regularly and as soon as it becomes dirty with a damp cloth.
Wipe the minibar dry with a cloth after cleaning.
Check the condensate drain regularly.
Clean the condensate drain when necessary. If it is blocked, the condensate collects on the bottom of the
minibar.
For absorber versions: Use a brush or so cloth annually to remove dust from the absorber unit.
9 Troubleshooting
Problem
The minibar is not cooling. The indica-
tor LED is off.
The minibar is not cooling. The indica-
tor LED is on.
Minibar is not cooling. Indicator LED
flashes orange for x times within a cer-
tain period of time.
14
Possible cause
Power plug is not plugged in.
No voltage at the socket.
The fuse of the electronics is defective.
For versions with absorber cool-
ing: Heating cartridge defective
Electronics or temperature sensors de-
fective.
Cooling unit is defective.
Minibar is in silent mode (C60 only).
Flashing 1x: NTC sensor is defective.
Flashing 3x: Heating cartridge is de-
fective (only for versions with absorber
cooling).
Flashing 5x: CPC (cooling perfor-
mance control) error.
Suggested remedy
Insert power plug into socket.
Check circuit breaker.
Contact an authorized service
agent.
Service agent only: Replace
the fuse.
Contact an authorized service
agent.
Service agent only: Install new
heating cartridge.
Contact an authorized service
agent.
Service agent only: Install new
electronics or sensor.
Contact an authorized service
agent.
Service agent only: Replace
the minibar.
No action required
(Setting the silent
mode (only for C40)
on page 12).
Contact an authorized service
agent.
Service agent only: Replace
the NTC sensor.
Contact an authorized service
agent.
Service agent only: Install a
new heating cartridge.
1.
Temporarily disconnect the mini-
bar from the power supply to re-
set the error.