BURNERS
MODEL
NOZZLE
NOZZLE OF BURNER 1/100 MM
FT**-30
CONSUPTION
NOZZLE OF BURNER 1/100 MM
FT**-60
CONSUPTION
NOZZLE OF BURNER 1/100 MM
FT**-90
CONSUPTION
PACKING AND DEVICE CHECK
The device leaves our stocks properly packed with appropriate symbols and labels. There are also appropriate
instructions for use. In case the packing shows bad handling or damage, it must be reclaimed at transporter
immediately by writing and signing of a damage protocol.
Important notice:
• this instructing guide must be read properly and carefully because it contains important information about
safety elements, installation, use
• these recommendations refer to this product
• this product corresponds with valid standards
• this guide must be properly deposited for future use
• keep the children away from manipulation with the product
• when selling or moving the product to another place it is necessary top make yourself sure that the staff
or the professional service has got acquainted with control and installation instructions from enclosed guide
• only authorised person can operate the product
• it can not be switched on without supervision
• we recommend to have the product checked by professional service min. once a year
• only original spare parts can be used for repairs
• the product can not be cleaned by the water jet or pressure shower
• by damage or break down disconnect all the feeders (water, gas, electricity) and call professional service
• producer refuses any responsibility in case of damages caused by wrong installation, by disobserving of
above mentioned recommendations or by other use etc.
PLACEMENT
The device must be instalated in well ventilated room what is necessary for regulation of the function of the
device (technician must go by valid standard (ČSN....). If the device is situated close to the wall or if it is in
contact with the furniture walls, these walls must resist the temperatures ranging to 60°C. Instalation, setting,
putting into operation must be done by qualifi ed person who is competent for this and according to the valid
standards.
Wrap up the device and check whether it was not damaged during transport. Settle the device on horizontal
surface (max imbalance 2°).Settle the device under the fumehood to eliminate water steam and bad smell.
The device can be instalated separately or in a set with devices of our production. Min. distance 10 cm
from other subjects must be kept.It is also necessary to prevent our product from contact with combustible
materials. In this case you must make corresponding changes to secure heat izolation of combustible parts.
Safety measures from the standpoint of the fi re protection according to ČSN 061008čl. 21:
12,8 kWh/kg
G 30/G 31
Burner
PROPAN / BUTAN
28 - 30 mbar
4,0 kW
93
4,0 kW
0,546 kg/h
2x 4,0 kW
93
2x 4,0 kW
1,092 kg/h
3x 4,0 kW
93
3x 4,0 kW
1,638 kg/h
12,8 kWh/kg
12,8 kWh/kg
G 31
G 30/G 31
PROPAN
PROPAN / BUTAN
37 mbar
50 mbar
93
77
0,546 kg/h
0,546 kg/h
93
77
1,092 kg/h
1,092 kg/h
93
77
1,638 kg/h
1,638 kg/h
9,45 kWh/m
3
FEEDING
G 20
TUBE
Natural GAS
GAS
20 mbar
135
G 1/2"
0,74 m
/h
---
3
135
G 1/2"
1,148 m
/h
---
3
135
G 1/2"
2,22 m
/h
---