5.
Attach the connector to the clips on the arm.
6.
Tighten the screw (Torx 20) on the arm of the
reference station.
4.1 Introduction - maintenance
Make a check of the installation each year.
1.
Make sure that the post is tightly attached.
Screw
Reference station to arm
Arm to post
Arm, support bracket and post bracket
8 - Maintenance
T20
7.
Connect the low-voltage cable to the reference
station and the power supply.
8.
Attach the low-voltage cable to the wall from the
reference station to the power supply with cable
ties.
9.
Put the power supply at a minimum height of 30
cm / 12 in. from the ground. Refer to
where to put the power supply on page 5 .
10. Connect the power supply cable to a 100-240V
power outlet.
11. Wait until the LED status indicator is solid green.
First the LED status indicator is flashing green for
some minutes. Refer to
reference station on page 9 .
4 Maintenance
2.
Make a check of the tightening torques for all
screws.
Tool
Torx 20
Hex key, 4 mm
Hex key, 4 mm
CAUTION:
If the low-voltage
cable is not attached tightly with cable
ties it can be damaged in hard wind.
To examine
LED indicator lamp on the
Tightening torque (Nm)
1.8
5-6
5-6
1512 - 001 - 11.11.2020