Digital SmartHandle AX Stationary installation
Locking and insurances
Insurance companies place increased demands on a
closure.
1. If you want to lock the door under insurance law,
use a self-locking panic lock or a locking cylinder in
addition to the SmartHandle AX.
2. Pay attention to the approvals according to EN 179.
SmartHandle AX with self-locking panic lock
The SmartHandle AX only offers full functionality with
a self-locking panic lock.
1. Combine the SmartHandle AX with a self-locking
panic lock.
2. Pay attention to the declarations of conformity of
the lock manufacturers according to EN 179.
Conditions for authorisation security
Operation with Mifare Classic and/or PinCode keypad
excludes authorisation security class D according to
DIN EN 16867:2020.
Sealing escutcheon holes
Any escutcheon holes that exist may be used to ma-
nipulate the lock.
1. Seal any escutcheon holes with a blind cylinder, for
example.
2. In the case of FH versions, you must be install a
brass dummy cylinder or locking cylinder.
4. Scope of delivery
SmartHandle AX (stationary installation)
Special tool
Quick guide
Depending on version:
Adapter set, 7 mm spindle
Adapter sleeve, 8.5 mm spindle
Adapter sleeve, 10 mm spindle
Blank cylinder
5. Design
1
6. Prepare door (drilling tem-
plate)
Pin or scriber at hand.
ü
Drill at hand.
ü
EN
ü
Suitable drill bit at hand (depending on mortise
lock hole diameter: 8.5 mm/9.5 mm/10.5 mm).
ü
PH2 screwdriver at hand.
1. Insert the spindle into the mortise lock.
2
2. Place the drilling template on the spindle.
3
3. Align the drill template vertically using the printed
scale.
4. Mark the points to be drilled on the door.
4
5. Remove the drilling template.
5
6. Remove the spindle.
6
7. Remove the mortise lock (PH2).
7
8. Measure the diameter of the fastening holes.
8
Ø fastening holes
5.5 mm–6.3 mm
6.4 mm–7.3 mm
7.4 mm–8.7 mm
≥ 8.8 mm
9. Determine the required drill bit based on the meas-
ured diameter.
10. Drill the required holes.
9
11. Fit the mortise lock (PH2).
10
7. For door thickness X: prepare
threaded rods and spindle
ü
Saw at hand.
ü
Vernier calliper at hand.
ü
PH2 screwdriver at hand.
1. For X: measure the door thickness.
11
2. For X: fasten the screws, threaded sleeves and
threaded rods together.
12
4. Scope of delivery
Drill bits required
8.5 mm
8.5 mm
9.5 mm
10.5 mm
49 / 92