Digital SmartHandle AX Scandinavian Oval
Conditions for authorisation security
Operation with Mifare Classic and/or PinCode keypad
excludes authorisation security class D according to
DIN EN 16867:2020.
Sealing escutcheon holes
Any escutcheon holes that exist may be used to ma-
nipulate the lock.
1. Seal any escutcheon holes with a blind cylinder, for
example.
2. In the case of FH versions, you must be install a
brass dummy cylinder or locking cylinder.
4. Scope of delivery
SmartHandle AX (Scandinavian Oval)
Special tool
Quick guide
Depending on version:
Adapter set, 7 mm spindle
Adapter sleeve, 8.5 mm spindle
Adapter sleeve, 10 mm spindle
Blank cylinder
5. Design
1
2
6. For door thickness X: prepare
threaded rods and spindle
ü
Saw at hand.
ü
Vernier calliper at hand.
ü
PH2 screwdriver at hand.
1. For X: measure the door thickness.
3
2. For X: fasten the screws, threaded sleeves and
threaded rods together.
4
3. For X: mark the sawing points on the threaded rods
and spindle.
5
6
7
EN
4. For X: use a suitable saw to cut the threaded rods
and spindle.
8
7. For inner door handle, clock-
wise: prepare stud bolts
ü
TX3 screwdriver at hand.
1. Check whether you need to turn the inner handle
clockwise.
9
If yes, refit the SmartHandle AX's stud nuts as
9
described.
2. Unscrew the SmartHandle AX rear (TX8).
10
3. Unscrew the stud nuts.
11
4. Re-fasten the stud nuts firmly in the new positions.
12
5. Screw the SmartHandle AX rear firmly into place
again (TX8, torque 1.1 Nm).
13
9
Stud nuts are fastened through the SmartHandle
AX rear again.
8. Programming the fitting
Programme the fitting before installation. You can use
different programming devices, depending on the
product family.
14
15
16
9. Installing the fitting
ü
Door pre-drilled.
ü
PH2 screwdriver at hand.
ü
TX15 screwdriver at hand.
ü
Vernier calliper at hand.
ü
Pincers at hand.
1. For S, M and L: measure the door thickness.
17
2. For S, M and L: determine the separation points on
the cut-to-length screws L1 and L2.
18
4. Scope of delivery
41 / 80