CONNECT TO REFRIGERATOR
CONNECT TO REFRIGERATOR
Parts Supplied
Parts Supplied
 1/4" to 1/4" (6.35 mm to 6.35 mm) male-to-male
 1/4" to 1/4" (6.35 mm to 6.35 mm) male-to-male
coupling (on some models)
coupling (on some models)
6"
(15.2 cm)
7"
(17.78 cm)
NOTE: The flexible, codes-approved water supply line
NOTE: The flexible, codes-approved water supply line
should connect to the supply valve through the floor.
should connect to the supply valve through the floor.
1.
1.
Unplug the refrigerator or disconnect power.
Unplug the refrigerator or disconnect power.
2.
2.
Connect the 7 ft (2.13 m) flexible codes-approved
Connect the 7 ft (2.13 m) flexible codes-approved
water tube to the water supply valve.
water tube to the water supply valve.
3.
3.
Flush the main water supply line to remove particles
Flush the main water supply line to remove particles
and air in the water line. Allow enough flow so that
and air in the water line. Allow enough flow so that
water becomes clear
water becomes clear
4.
4.
Tape the 7 ft (2.13 m) flexible codes-approved water
Tape the 7 ft (2.13 m) flexible codes-approved water
supply line to the floor, 7" (17.78 cm) from the left
supply line to the floor, 7" (17.78 cm) from the left
side of the refrigerator. Tape along the length of
side of the refrigerator. Tape along the length of
the tubing, which will allow it to pass beneath the
the tubing, which will allow it to pass beneath the
refrigerator without interference.
refrigerator without interference.
NOTE: Allow a minimum of 26" (66.04 cm) of flexible
NOTE: Allow a minimum of 26" (66.04 cm) of flexible
codes-approved water supply line to be loose at
codes-approved water supply line to be loose at
the front of the refrigerator for connecting to the
the front of the refrigerator for connecting to the
refrigerator.
refrigerator.
5.
5.
Connect the 7 ft (2.13 m) flexible codes-approved
Connect the 7 ft (2.13 m) flexible codes-approved
water supply line to the refrigerator.
water supply line to the refrigerator.
NOTE: If the main water shutoff valve is behind the
NOTE: If the main water shutoff valve is behind the
refrigerator, a secondary water shutoff valve may be
refrigerator, a secondary water shutoff valve may be
installed in line with the water supply line at the front
installed in line with the water supply line at the front
of the product.
of the product.
6"
(15.2 cm)
1"
(2.54 cm)
OVERMOLD COUPLING (ON SOME MODELS)
OVERMOLD COUPLING (ON SOME MODELS)
A. Household water line
A. Household water line
B. Nut (purchased)
B. Nut (purchased)
C. Ferrule (purchased)
C. Ferrule (purchased)
DISCRETE COUPLING (ON SOME MODELS)
DISCRETE COUPLING (ON SOME MODELS)
C
C
B
B
A
A
A. Household water line
A. Household water line
B. Nut (purchased)
B. Nut (purchased)
C. Ferrule (purchased)
C. Ferrule (purchased)
D. Coupling
D. Coupling
6.
6.
Turn on the water supply valve and check all
Turn on the water supply valve and check all
connections for leaks.
connections for leaks.
C
C
A
A
B
B
D
D
F G
F G
E
E
E. Bulb
E. Bulb
F. Nut
F. Nut
G. Refrigerator water tubing
G. Refrigerator water tubing