5. Reset to factory setting
Press the pin button for 3 secs. and the thermostat returns to factory settings. Time,
day and scale for time (12h, 24h) and temperature (˚F, ˚C) read-out are also reset and
must be set according to "Setting the thermostat into operation".
Factory settings
4-event time and temperature
Day 1-5
Time
06:00 a.m.
08:00 a.m.
4:00 p.m.
10:00 p.m.
Day 6-7
08:00 a.m.
11:00 p.m.
4-event sequence
5:2
Hi-Low temp.
131˚F / 41˚F
Scale
12 H / ˚F
Adaptive control
ON
6. Failure codes
E0 =
Internal failure, replace thermostat
E1 =
Built-in sensor short-circuit or disconnected,
replace thermostat
E2 =
External sensor short-circuit or disconnected
7. Technical data
Supply: . . . . . . . . . . . . . . . . . 120/240V AC 50/60 Hz
Load:
. . . . . . . . . . . . 15A maximum (resistive load)
Power:
. . . . . . . . . . . . . . . . . . . 1.800 W at 120V AC
GFCI:
. . . . . . . . . . . . . . . . . . . . . . . . 5 mA trip level
Temperature range: . . . . +5 to +40°C, +40 to +104˚F
Amb. Temperature range:
Thermostat: . . . . . . . . . . . 0 to +40°C, +32 to +104˚F
GFCI:
. . . . . . . . . . . . . -35 to +65°C, -31 to +149˚F
OJ ELECTRONICS A/S
Stenager 13B · DK-6400 Sønderborg
Tel. +45 73 12 13 14 · Fax +45 73 12 13 13
oj@oj.dk · www.oj.dk
4
UCCG-9991
w/floor sensor
77˚F / 25˚C
68˚F / 20˚C
77˚F / 25˚C
68˚F / 20˚C
77˚F / 25˚C
68˚F / 20˚C
OFF/OFF
3.600 W at 240V AC
© 2008 OJ Electronics /S - ® The OJ trademark is a registred trademark belonging to OJ Electronics /S
UCCG-9999
UCDG-9999
w/room sensor
w/dual sensor
68˚F / 20˚C
68˚F / 20˚C
59˚F / 15˚C
59˚F / 15˚C
70˚F / 21˚C
70˚F / 21˚C
59˚F / 15˚C
59˚F / 15˚C
70˚F / 21˚C
70˚F / 21˚C
59˚F / 15˚C
59˚F / 15˚C
OFF/OFF
82˚F / 59˚F