Checking GFCI
It is important that the GFCI has been checked for correct installation and function.
To check the GFCI: Testing can only be performed if the thermostat has a heating demand. Adjust the set point until the heating symbol (SSS) appears, use the
(
), to increase the heating demand. Wait 10 secs. to let the thermostat work according to the new set point. Press the button "TEST". The test is conclusive if
the red light on the thermostat lightens, and the display signs disappear. If this does not occur, check the installation. Press on RESET button to reset the GFCI.
The red light should disappear and the display will return to normal appearance. Push ok accept button (
fails, check your heating cable and the thermostat. The GFCI test should be carried out monthly.
If the GFCI trips in normal operation, without pressing the TEST button, there could be a ground fault! To check whether it is a ground fault or a nuisance
tripping, press RESET. If this cause the red light to shot off and not comes on again, it was a nuisance tripping and the system is functioning. If this cannot be
done there is a ground fault! Check your heating cable, the sensor cable and the thermostat.
Exchange the defective part.
2. Daily use of the thermostat
4-event clock mode
The day has been split into 4 events describing a typical day. When the thermostat is in 4-
event mode it will automatically adjust the temperature according to the required temperature
to the required time. As standard the thermostat has 5 days with 4 events, and 2 days with 2
events. Programming see 3.
4-event clock mode:
Comfort mode:
5 secs.
Manual mode:
5 secs.
OFF
3. Programming
4-event time and temperature
For each event, the start time and required temperature must be
set.
For example, in the morning you wish the heating to start at
07:00 a.m. and the temperature to rise to 77˚F. Press OK ( )
button for 3 seconds and the start time is displayed. Change
this to 07:00 a.m. with the UP (
OK ( ) to confirm.
The temperature is now displayed. Change this to 77˚F with the
UP (
) or DOWN (
) button.
Press OK ( ) button to confirm. This action can now
be repeated for the second event.
These settings will be valid with days 1-5 showing on the
display. To program the days 6 and 7, repeat the above. Days 6
and 7 are usually Saturday and Sunday, and only have two
events.
The temperature can be set within the range of +41°F to +104˚F.
It is also possible to select the heating OFF at that event by
reducing the setting to 41˚F, and then pressing the ( ) once
more.
2
The clock function symbol (
Programming see 3.
Temporary override: To temporarily override the temperature in the 4-event schedule program, press the UP (
DOWN (
) button once, to show the temperature, and press again to increase or decrease the temperature.
The display will flash for 5 seconds, and will then revert to the time. The override will operate until the next
programmed event when the unit will resume the automatic program.
Cancel comfort mode:
To cancel the override state, press the OK (
Permanent override:
During holidays, the scheduled 4-event program can be overridden. Press the OK ( ) button, and then the UP ( ) or
DOWN (
) button until the override temperature is set. The unit will now operate to this temperature permanently.
Cancel manual mode:
To cancel the permanent override state press the OK ( ) button once, and the unit will resume automatic function.
To turn the thermostat OFF, press DOWN (
DO NOT USE THE TEST BUTTON ON THE GFCI TO SWITCH OFF THE HEATING INSTALLATION.
The GFCI will automatically be reset after a disconnection of the mains supply
) or DOWN (
) button. Press
) and one of the 4-event symbols (
) button twice.
) until OFF appears in the display.
Press OK (
) button for 3 secs. to begin programming
Day 1 - 5
Day 6 - 7
© 2008 OJ Electronics /S
) to cancel the previously set temperature. If the test
) will be indicated.
: Time and temperature
: Time and temperature
: Time and temperature
: Time and temperature
: Time and temperature
: Time and temperature
) or