Télécharger Imprimer la page

Victron energy Compact 12/1200 230V Manuel page 15

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 35
5.5.2 Configuration examples
Example 1 is the factory setting (since factory settings are entered by computer, all DIP
switches of a new product are set to 'off', except for DS-2).
DS-1 Panel option
DS-2 Panel option
DS-3 Not used
DS-4 Not used
DS-5 Frequency
DS-6 Search mode
DS-7 Not used
DS-8 Store setting
Example 1: (factory setting)
1
No panel connected
2
No panel connected
5
Frequency: 50 Hz
6
Search mode off
8 store setting: off→ on→ off
Store the settings (DS3-DS7) by changing switch ds-8 from off to on, and then back to off.
The LED's "Inverter" and "eco mode" and "alarm" will flash four times to indicate
acceptance of the settings.
off
DS-1
off
on
DS-2
DS-3
DS-4
off
DS-5
off
DS-6
off
DS-7
→ ←
→ ←
DS-8
Example 2
1
2
5
6
8 store setting: off→ on→ off
13
DS-1
on
DS-2
DS-3
DS-4
on
DS-5
DS-6
DS-7
DS-8
Example 3
No panel connected
1
No panel connected
2
Frequency: 60 Hz
5
Search mode off
6
8 store setting: off→ on→ off
on
off
on
on
→ ←
Panel connected
Panel connected
Frequency: 60 Hz
Search mode on

Publicité

loading

Ce manuel est également adapté pour:

Compact 24/1200 230vCompact 12/1600 230vCompact 24/1600 230v