Detailed Performance Data for the TMC 300 R on Round Pipes
Values shown for the performance of the TMC 300 R are based on measurements made on round pipes with
material S235 JR, comparable to AISI 1020 Cold Rolled Steel, for the maximum, vertical breakaway force at
0° deviation from the load axis and a correct position in the groove of the magnetic contact area. These values do
not include any safety factor. The magnetic clamp will detach itself abruptly when the load exceeds values given in
table 3.
Tabelle 3 Round pipes
mm
25
2
72
3
77
4
81
>5
90
inch
1"
0.08
158
1/8
169
0.16
178
>0.2
198
Avoid quick and abrupt rotations of the magnetic clamp especially when used on round objects
since the workpiece could disengage from the groove of the magnet causing a sudden reduction
of the load-bearing capacity.
20
Breakaway force in kg
50
75
96
120
102
128
108
135
120
150
Breakaway force in lbs
2"
3"
211
264
224
282
238
297
264
330
100
200
96
-
102
-
108
-
120
-
4"
8"
211
-
224
-
238
-
264
-

Publicité