Télécharger Imprimer la page

Parker Maxi Plus MPXE 106 Mode D'emploi page 24

Publicité

Les langues disponibles
  • FR

Les langues disponibles

COLUMNS
*
Omission or use of incorrect snowstorm filling devices.
*
Excessive exposure of desiccant to atmosphere during filling.
*
Hand filling or 'topping up' without correct filler.
*
Leaving desiccant media in bolt holes when torquing down top manifold bolts.
*
Failure to remove all desiccant from column during desiccant change.
TOP MANIFOLD/OUTLET VALVE
*
Incorrect torquing of column bolts - sequence tightening must be employed.
*
Use of non TS dust filters on DHE Models.
*
Use of sonic nozzles for flow measurement.
*
Cleaning of column bolts before torquing.
*
Faulty torque setting.
*
Use of incorrect wire stripping tools.
CONTROL BOX
*
Excessive voltage drop on incoming supply.
*
Purge setting by amps, non-use of flow meters.
*
Incorrect fusing used (external).
*
Incorrect supply wire (incoming).
*
No earth wire between earth terminal and armour cable clamp on shroud.
ADDITIONAL ITEMS
*
Use of non-recommended desiccant or non-genuine domnick hunter spare parts from alternative suppliers.
*
Servicing undertaken by untrained distributor/OEM personnel.
*
Inability to maintain inlet pressure and temperature at levels stated for sizing.
*
Not to use dryer/dryers if piped directly after a portable compressor.
FASCIA
*
Depression of press buttons with sharp objects (e.g. keys, screwdrivers etc).
*
Subjected to bulk water spray.
*
Operation of the dryer with control fascia open.