TROUBLE SHOOTING
SYMPTOM
HighlimitswitchOpenCircuit
Sparks,callingforflame,but
noorslowmotoroperation
NoSpark
AbnormalMotorOperation-
MotoroverheatsorStops
UnabletoDetectFlame
FlameControlFailure
TROUBLE SHOOTING
1) Makesureheateriscooledoff,toggleswitchto"OFF"position,wait5minutesandretry.
1) Checkwiringtomotor(perwiringschematicinmanual).
2) Makesurethatthepressuregaugeisinplaceandnotdamaged.
3) Adjustpressureforproperheateroperationpermanual.
4) WithheaterdisconnectedfromACsource,rotatefanclockwisetoverifymotorisfree.
5) Removeairfilterhousingfrommotorandinspectthepumprotorfordamage.Ifdamaged,replacerotorassembly.
6) Ifwiringiscorrect,pumprotorisokay,andmotorisnotrotatingfreely,replacemotororpower-packassembly.
7) Ifproblempersists,replaceoilflamecontrolassembly.
8) Checkforsparkarchingfromtheelectrodeassembly,tothecombustioncylinder.
9)
Checkthecadcellforcontinuity.
1)
Checklengthandgageofextensioncordforproperamp.draw.(Checkrequirementsonpage4.)
2) Checkwiringtoigniter(perwiringschematicinmanual).
3) Checkgapbetweenelectrodeprobes(2.3-3mm).
4) Stillnospark,replaceigniterassembly.
5) Replaceoilflamecontrolassembly.
1) Motorspeedtoolow(Motorshouldoperateat3450rpm)-Replacemotor.
2) WithheaterdisconnectedfromACsource,rotatefanclockwisetoverifymotorisfree.
3) Removeairfilterhousingfrommotorandinspectthepumprotorfordamage.Ifdamaged,replacerotor
assembly.
4) Ifwiringiscorrect,pumprotorisokay,andmotorisnotrotatingfreely,replacemotororpower-packassembly.
5) Replaceoilflamecontrolassembly.
1) Checkwiringtocadcell(perwiringschematicinmanual).
2) Cleancadcellphotocell.
a) Slidecadcelloutofcadcellholder.
b) Pushthephotocelloutoftheblackrubbercadcellhousingbypushingonthe2purplewires.
c)
Cleanthephotocellwithasoftclothandrubbingalcohol.
d) Pullthephotocellbackintothecadcellhousingandreinstallintoholder.
e) Testheater.
3) Iftheheaterstilldoesnotoperate,replacecadcell.
4) Replaceoilflamecontrolassembly.
1) Checkwiringinheater(perwiringschematicinmanual).
2) Replaceoilflamecontrolassembly.