INSTALLATION INSTRUCTIONS
The installation must be performed by a qualified electrical contractor. This contractor will take
the entire responsibility of the installation. The installation has to comply with the legislation and
the standards in force in your country.
How to stick the gasket:
The gasket supplied with the hob prevents the intrusion of liquids into the cabinet below.
Its installation has to be done carefully, as described below.
Aeration
Fitting - installing:
• Cut out sizes of the worktop:
KI9810.0SF
KI9810.0SR
• Ensure that there is a distance of 40 mm between the hob and the wall or sides.
• The hobs are classified as "Y" class for heat protection. Ideally the hob should be installed
with plenty of space on either side. There may be a wall at the rear and tall units or a wall
at one side. On the other side, however, no unit or divider must stand higher than
the hob.
• The piece of furniture or the support in which the hob is to be fitted, as well as the edges of
furniture, the laminate coatings and the glue used to fix them, must be able to resist
temperatures of up to 75 °C.
• The mural rods of edge must be heat-resisting.
• Not to install the hob to the top of a not ventilated oven or a dishwasher.
A
900 mm
520 mm
898 mm
518 mm
Stick the gasket (2) two millimeters
from the external edge of the glass,
after removing the protection tape (3).
B
E
750 mm
750 mm
37
F
H
490 mm
48 mm
490 mm
48 mm