Green LED on: the system is in test mode.
Green LED blinking: in Test mode, this indicates flat battery.
Orange LED on for 5 seconds: the system is in normal operating mode.
The orange LED blinks for 5 seconds: it indicates flat battery in normal operating mode.
S
S
Y
Y
S
S
T
T
E
E
M
M
S
S
T
T
A
A
T
T
E
E
L
L
E
E
D
D
(
(
G
G
R
R
By pressing the
button, the system status will be checked:
Red LED on for 3 seconds: the system is in Total Armed state.
Red LED blinking for 3 seconds: the system is in Partial Armed state.
Green LED on for 3 seconds: the system is OFF.
F
A
U
L
T
L
E
D
(
O
R
A
N
G
E
)
F
A
U
L
T
L
E
D
(
O
R
A
N
G
E
)
During the whole or partial system activation procedure:
Blinking 4 times: system error (control unit tamper, power fault, detector tamper, detector fault, door open, etc.)
On: alarms have occurred.
T
a
m
p
e
r
p
r
o
t
e
c
t
i
o
n
T
a
m
p
e
r
p
r
o
t
e
c
t
i
o
n
The keypad is protected from any attempt to open the cover or remove it from the installation surface.
The Tamper protection is not on when the keypad is in Test mode.
T
e
s
t
m
o
d
e
T
e
s
t
m
o
d
e
The remote keypad may be set to test mode by entering the keypad code (default: 0000) followed by button
state LED lights up and a long beep will sound.
To exit test mode, press the
switched off and the remote keypad will return to normal operating mode. Otherwise, the remote keypad will automatically
shut down Test mode after 5 minutes and go back to normal operating mode.
L
e
a
r
n
i
n
g
p
r
o
c
e
d
u
r
L
e
a
r
n
i
n
g
p
r
o
c
e
d
u
r
Set the control unit to learn mode.
Step 1:
Step 2:
Add the remote keypad in the control unit in one of the following two ways:
1) TEST MODE LEARNING
I. Set the remote keypad in Test mode by entering the keypad code (pre-set: 0000) followed by button
LED lights up and a long beep will sound.
II. Press button
long beep.
III. The respective information will be shown if the control unit receives the learning data. Refer to the control unit instruction
manual to complete the learning procedure.
IV. After having received the remote keypad signal, the control unit will send a confirmation to the remote keypad. The remote
keypad will beep three times to confirm that validation was received.
4
E
E
N
/
O
R
A
N
G
E
)
:
E
E
N
/
O
R
A
N
G
E
)
:
E
E
E
E
N
N
/
/
R
R
E
E
D
D
)
)
:
:
button twice, the remote keypad will generate a long beep, the keypad state LED will be
e
e
and then button 7. The remote keypad sends the learning command to the control unit and generates a
1. Keypad state LED
2. System state LED
3. Fault LED
4. Arming button
5. Partial arming button
6. Button
: system state check request
7. Disarming button
8. Mounting holes
9. Panic alarm buttons (if enabled).
10. Learn data buttons.
11. Mounting holes
12. Tamper switch
13. Battery isolator
. The green
. The green state