CONSUMABLES INSPECTION (ASSEMBLY AND DISASSEMBLY, SEE P.16)
Parts
Check the for damage and surface wear.
Nozzle
Visually check the tip's internal hole.
Tip
Check for damage and wear on the surface and inside the diffuser.
Check that the fumes' exhausts are not obstructed.
Diffuser
Visually check the electrode's internal hole.
Electrode
TROUBLESHOOTING
Anomalies
At startup, the display shows 'Er1'
At startup, the display shows 'Er2'
At startup, the display shows '- - -'
In operation, the display shows '- - -'
The machine delivers no power and the
indicator (3) is on
The machine delivers no power and the
indicator (4) is on
The display shows 'no Air'
The machine delivers no power and the
display shows 'Er3'
The machine delivers no power and the
display shows 'Er4'
The display shows 'Er5'
PLASMA CUTTER 40 FV
Actions
OK
OK
Causes
The device was turned on with the trigger
pressed
One or more buttons on the keypad are
pressed
The machine is connected to an unsuitable
power supply (out of 85-265V range)
The overvoltage protection is active.
The thermal protection of the Plasma Cutter
is active
The torch nozzle is not in place
The air pressure is too low
No contact between the electrode and the
nozzle
The electrode cannot retract
The cutting cycle has stopped abnormally
Solutions
Replace the nozzle when it looks damaged (traces of
burns).
Replace the tip if the inner diameter is enlarged or
distorted.
NOK
Replace the diffuser if the surface is damaged or
worn, or if fume exhausts are obstructed.
Replace electrode when the insert is used (removal of
1.5 mm).
NOK
Release the trigger
Release the button(s)
Check the electrical system or generator
Wait until the end of the cooling phase
Turn off the machine, check and replace the
consumables, turn on the machine
Check that the air supply is properly connected
to the machine, adjust the air pressure
Turn off the product, check the
consummables, check the electrode retracts
and returns easily. Try again.
Turn off the product, make sure that the
electrode can retract and return easily. Try
again
Turn off the product, wait until the error
disappears, try again. If the error persists
return the product for inspection
EN
Remedies
19