Télécharger Imprimer la page

Chamberlain MotorLift HC100ML-2 Mode D'emploi page 17

Masquer les pouces Voir aussi pour MotorLift HC100ML-2:

Publicité

Les langues disponibles

Les langues disponibles

TYPICAL SYSTEM SET-UP
(1) Drive with control unit
(2) Control unit (if fitted externally)
(3) Infrared Sensor - transmitter
(4) Infrared Sensor - receiver
(5) Flashing lamp
(6) Antenna (optional)
(7) Key Switch (optional)
(8) Infrared Sensor (optional)
(9) Infrared Sensor (optional)
1
3 3
2 2
8 8
2
INSTALLATION
(1) F1
Main fuse (230Volt)
(2) F2
Secondary fuse 24Volt ~
(3) F3
Central fuse (logic circuitry)
(4) C
Brake
(5) B
Pause (gate waits in open position)
(6) M5
Socket plinth for radio (model 801719)
(7) A
Opening and closing force
(8) LED 5
Limit switch monitor
(9) LED 6
Limit switch monitor
(10) LED 4
Infrared Sensor (monitor)
(11) LED 3
B push-button input
(12) LED 2
A push-button input
(13) LED 1
STOP (emergency stop)
(14) LED 7
Diagnosis (general)
(15) M1 – M4
Connection terminals
(16) M6
Connection accessories (not needed)
(17) SW1
Programme switch (DIP switch)
(18) TEST
Test push-button (opens fully)
1
16
15
17
709207B-GB - 05.2004
All manuals and user guides at all-guides.com
1
5 5
7 7
4 4
8 8
9 9
1 1
2
3
11
13
12
14
18
CONNECTIONS
M1
1- L
2- Earthing
3- N (zero conductor)
4- L
5- L
M2
6- L close
7- N (zero conductor)
8- L open
9 9
M3
9- LED –
10- LED +
11- COM (common)
12- STOP (NC)
13- Push-button A (NO)
14- Push-button B (NO)
15- COM (common)
16- LS contact (NC)
M4
17- OPEN (NC)
18- COM (common)
19- CLOSE (NC)
20- L
21- L
4
5
6
7
8
9
Flashing lamp
10
3x1,5mm
230V~ ±10% 50Hz
SUPPLY LINE
3
230Volt
L 230V/ 50Hz +/- 10%
Power supply to control unit, drive,
accessories
230Volt~
Flashing lamp (230Volt~)
Drive connection 230 volt~ 700VA
max.
Capacitor is connected between 6
and 8
Gate status LED
Indicates whether gate is OPEN or
CLOSED
Push-button inputs
A= open gate fully
B= partially open gate
Infrared Sensor connection
Limit switch connection
Pre-fitted for right-hand installation
Power supply to accessories 24 volt~
+/-5% 500mA
3x1,5mm
3x1,5mm
M
4
Opening
Closing
limit-stop
limit-stop
LIMIT SWITCHES

Publicité

loading

Ce manuel est également adapté pour:

Motorlift hc500ml-2