Télécharger Imprimer la page

BIEMMEDUE GA/N 115C Manuel D'instructions page 62

Masquer les pouces Voir aussi pour GA/N 115C:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 23
Warning
Never attempt to switch the heater on or off by connecting the room thermostat (or other control devices) to
the electrical power line.
5.2.3 Connection to climate control system
The space heater has been set up for connection to a remote climate control system:
therefore, the heating function (button A), the ventilation function (button B), the
voltage warning lamp signal display (lamp E) and the reset button warning lamp (lamp
D) can all be managed.
Warning
It is possible to display only the block signal and not manage the reset button
function (D).
The manual reset function must always be used only and exclusively after
having understood the reason for the safety lockout.
The electrical connection must be made using the 9-element terminal block on the
upper part of the electronic connection board. Use only interconnection relays (not
supplied with the heater) with electrical specifications (voltage and frequency)
compatible with those of the available climate system.
L-L 337.00-BM
Connector J18
Voltage Warning Lamp E
When the power supply line
is
connected,
the
terminals will have 220 V
AC - 1 A max.
Connector J20
Ventilation button (B)
If the two J20 connector
terminals are connected
together with a jumper, the
fan will run continuously. If
the two J20 connector
terminals
are
connected
together
jumper), the fan will run
only
when
the
heating
function is active (including
pre-ventilation and post-
ventilation phases).
EN
J18
not
(no
Connector J21
Safety
Lockout
Warning
Lamp D
When the heater is in safety
lockout, the J21 terminals
will have 220 V AC - 1 A
max.
Connector J52
Heating button (A)
If the two J52 connector
terminals are connected
together with a jumper, the
heating function will be
active and the burner flame
will be lit. If the two J52
connector terminals are not
connected
together
jumper),
the
heating
function is not active and
the burner flame will be off.
62 / 116
(no

Publicité

loading