Troubleshooting And Maintenance - REV MAX Mode D'emploi

Masquer les pouces Voir aussi pour MAX:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

17. Troubleshooting and maintenance

Error code on
the display
Battery symbol 
(
)
F1
F2
F3
F4
Symbol for radio 
synchronicity 
flashing slowly (
Symbol for radio 
synchronicity 
flashing fastly (    )
LOC
CAL
30
Problem
Battery voltage 
too low
Valve drive sluggish Check the installation; 
Actuating range 
too wide
Actuating range too 
narrow
A MAX! Cube 
has already been 
taught-in
Connection to 
taught-in MAX! 
)
Components lost
Duty cycle has 
been exceeded
Operating block 
activated
Routine descaling 
is active
Solution
Replace batteries
check whether the pin on 
the heating valve is stuck
Check the fastening of 
the actuator
Check the heating valve; 
check whether the valve 
pin is jammed
Reset the device and 
repeat the teach-in 
procedure
Check the power supply 
to taught-in MAX! 
Components
The longest period to 
wait before sending 
again would be an hour
Follow the instructions 
in the section 13 to 
deactivate the operating 
block
Automatic function, see 
the section 16

Publicité

Table des Matières
loading

Table des Matières