• Pull the thermostat dial off the valve (C).
Some valves require the use of an adapter. Adapters
for Danfoss valves (RA, RAV, RAVL) are supplied with
the product. For more details, please see the list of
adapters on page 18.
• Attach the valve adapter to the valve
and turn to secure.
• If you are using an RAV adapter, also
attach the extension supplied to the
valve tappet.
• Use the screw and nut supplied for
additional fastening of RA and RAV
adapters.
Once the batteries have been inserted, the motor
reverses; meanwhile, "InS" and the activity symbol (
)
are displayed. As soon as "InS" is displayed without the
activity symbol (
), the electronic radiator thermostat can
be mounted. This is followed by an adapter run ("AdA") to
adapt the thermostat to the valve.
• Attach the radiator thermostat to the valve.
• Tighten the union nut.
• Press the boost button when "InS" is displayed.
The actuator performs an adapter run. "AdA" and the
activity symbol (
) are displayed; during this time,
operation is not possible.
If the adapter run has been initiated prior to mounting or if
an error message (F1, F2, F3) is displayed, press the Boost
button; the motor reverses to the "InS" position.
23