• Pull the thermostat dial off the valve (C).
Some  valves  require  the  use  of  an  adapter.  Adapters 
for  Danfoss  valves  (RA,  RAV,  RAVL)  are  supplied  with 
the  product.  For  more  details,  please  see  the  list  of   
adapters on page 18.
• Attach the valve adapter to the valve  
  and turn to secure.
• If you are using an RAV adapter, also 
  attach the extension supplied to the  
  valve tappet.
• Use the screw and nut supplied for 
  additional fastening of RA and RAV  
  adapters.
Once  the  batteries  have  been  inserted,  the  motor   
reverses; meanwhile, "InS" and the activity symbol (
are displayed. As soon as "InS" is displayed without the 
activity symbol (
), the electronic radiator thermostat can 
be mounted. This is followed by an adapter run ("AdA") to 
adapt the thermostat to the valve.
• Attach the radiator thermostat to the valve.
• Tighten the union nut.
• Press the boost button when "InS" is displayed.
The  actuator  performs  an  adapter  run.  "AdA"  and  the   
activity  symbol  (
)  are  displayed;  during  this  time, 
operation is not possible.
If the adapter run has been initiated prior to mounting or if 
an error message (F1, F2, F3) is displayed, press the Boost 
button; the motor reverses to the "InS" position.