If the duration of the boost function (e.g. via the MAX! 
Cube) is set so that the display exceeds 999 seconds, 
the display value switches from seconds to minutes. 
 
 
The  actuator  reduces  the  temperature  in  the  room   
automatically during ventilation, in order to save on heat-
ing costs. During ventilation, the window open symbol (
is displayed.
Without MAX! Window Sensor:
A  MAX!  Radiator  Thermostat  is  able  to  automatically   
detect a sharp fall in temperature caused by ventilation   
(temperature  fall  detection).  The  temperature  is  then   
reduced to 12°C for 15 minutes (default factory setting).
With MAX! Window Sensor:
When a MAX! Window Sensor is used, the opening and 
closing  of  a  window  is  detected  at  the  precise  time  it   
occurs.  Whilst  the  window  is  open,  the  temperature  is   
reduced  to  the  factory  setting  of  12°C.  When  the  MAX! 
Window  Sensor  detects  the  closing  of  the  window,  all 
MAX!  Radiator  Thermostats  installed  in  the  room  are   
immediately reset to their original mode.
The  open-window  temperature  and  time  can 
be  set  via  the  MAX!  Software.  Temperature  fall   
detection without a MAX! Window Sensor can also be   
deactivated (by setting the duration to 0 minutes) 
via the software.