If the duration of the boost function (e.g. via the MAX!
Cube) is set so that the display exceeds 999 seconds,
the display value switches from seconds to minutes.
The actuator reduces the temperature in the room
automatically during ventilation, in order to save on heat-
ing costs. During ventilation, the window open symbol (
is displayed.
Without MAX! Window Sensor:
A MAX! Radiator Thermostat is able to automatically
detect a sharp fall in temperature caused by ventilation
(temperature fall detection). The temperature is then
reduced to 12°C for 15 minutes (default factory setting).
With MAX! Window Sensor:
When a MAX! Window Sensor is used, the opening and
closing of a window is detected at the precise time it
occurs. Whilst the window is open, the temperature is
reduced to the factory setting of 12°C. When the MAX!
Window Sensor detects the closing of the window, all
MAX! Radiator Thermostats installed in the room are
immediately reset to their original mode.
The open-window temperature and time can
be set via the MAX! Software. Temperature fall
detection without a MAX! Window Sensor can also be
deactivated (by setting the duration to 0 minutes)
via the software.
11. Open window function
)