Télécharger Imprimer la page

Maytag MAT14PRAWW Instructions D'installation page 4

Publicité

Les langues disponibles

Les langues disponibles

Recessed Area and Closet Installation Instructions
This washer may be installed in a recessed area or closet.
The installation spacing is in inches and is the minimum
allowable. Additional spacing should be considered for ease of
installation, servicing, and compliance with local codes and
ordinances.
If closet door is installed, the minimum unobstructed air openings
in the top and bottom are required. Louvered doors with
equivalent air openings are acceptable.
17"
(432 mm)
0"
(0 mm)
(0 mm)
Recessed front view
48"
2
(3.10 m
2
)*
Front view
24"
2
(1.55 m
2
)*
*Opening is the minimum for a closet door.
Louvered doors with equivalent air openings are acceptable.
Additional spacing should be considered for the ease of
installation and servicing.
Additional clearances may be required for wall, door and floor
moldings.
Additional spacing of 1" (25 mm) on all sides of the washer is
recommended to reduce noise transfer.
Companion spacing should also be considered.
4
All manuals and user guides at all-guides.com
Closet door
14"
48"
2
(356 mm)
(3.10 m
2
)*
max.
24"
2
(1.55 m
2
)*
0"
1" (25 mm)
min.
Closet side view
3" (76 mm)
closet
door
3" (76 mm)
Product Dimensions
A
B
C
4"
(102 mm)
min.
Standpipe Drain System
The standpipe drain requires a minimum diameter standpipe of
2" (50 mm). The minimum carry-away capacity can be no less
than 17 gal. (64 L) per minute.
The top of the standpipe must be at least 39" (990 mm) high and
no higher than 72" (1.8 m) from the bottom of the washer.
H
D
Cold
Hot
G
E
F
M
N
A.
43" (1090 mm)
B.
38¹⁄
"(970 mm)
8
C.
35" (890 mm)
D.
1¹⁄
" (38 mm)
2
E.
27¹⁄
" (705 mm)
4
F.
25¹⁄
" (650 mm)
2
G.
Water inlets
H.
7" (180 mm)
I.
Power supply cord
J.
Drain hose connector
K.
Label
L.
27" (685 mm)
M.
5¹⁄
" (133 mm)
4
N.
1" (25 mm)
O.
5" (127 mm)
Drain System
I
K
J
H
P
L

Publicité

loading