Low Idle Switch
NOTICE
Always start the generator with LOW IDLE SWITCH
on OFF position. Allow the engine speed to stabilize
and the OUTPUT READY INDICATOR LED to
illuminate green before switching LOW IDLE Switch
to ON position.
NOTICE
For periods of high electrical load or momentary
fluctuations, the LOW IDLE Switch should be turned
OFF.
NOTE:
LOW IDLE minimizes fuel consumption and noise by
adjusting the engine speed (RPM) to the minimum
required for the current load. Turn LOW IDLE Switch
to ON position when powering small appliances with
continuous loads such as a computer or electric light.
Turn LOW IDLE Switch to OFF position when
powering large surge loads such as an air conditioner
or electric pump. Be certain that the OUTPUT READY
INDICATOR LED is illuminated green before turning
the switch to ON position. If no load is present, the
generator speed (RPM) will drop to idle speed. The
generator will detect loads as they are applied and
increase engine speed (RPM). To run the generator
at maximum power and speed (RPM), push the LOW
IDLE Switch to the OFF position.
Stopping the Engine
1. Turn off and remove entire electrical loads.
Never start or stop the generator with electrical
devices plugged in or turned on.
Let the generator run at no-load for two minutes to
stabilize internal temperatures of the engine and
generator.
2. Turn the engine switch to the "OFF"(O) position.
3. Turn the fuel switch to the "OFF"
4. Turn the fuel cap vent lever to the "OFF" position.
WARNING
Page 18
position.
OFF