3. Installation diagram
Fig. 3-1
4. Installing the indoor unit
1
3
5
Fig. 4-1
J
7.5 - 24.5
88
Min. 450 H
150
K
F
Fig. 4-2
D
A
B
C
2
4
6
(576) C
625 D
576 - 610 C
7.5 - 24.5
408
I
525 B
570 A
*1
E
G
Floor
3.1. Indoor unit (Fig. 3-1)
(mm)
A Ceiling
B Grille
C Obstacle
D Min. 1000 mm
E Min. 500 mm (Entire periphery)
If setting the maintenance space for E, be sure to leave is a minimum of 700 mm.
Warning:
Mount the indoor unit on a ceiling strong enough to withstand the weight of
E
the unit.
3.2. Outdoor unit
Refer to the outdoor unit installation manual.
4.1. Check the indoor unit accessories (Fig. 4-1)
The indoor unit should be supplied with the following accessories.
Installation template
1
Washers (with insulation)
2
Washers (without insulation)
Pipe cover (for refrigerant piping joint)
Small diameter (liquid)
3
Large diameter (gas)
Band (large)
Band (middle)
4
Band (small)
Drain socket
5
Insulation
6
4.2. Ceiling openings and suspension bolt installation
(mm)
locations (Fig. 4-2)
Caution:
Install the indoor unit at least 2.5 m above floor or grade level.
For appliances not accessible to the general public.
• Using the installation template and the gauge (supplied as an accessory with the
grille), make an opening in the ceiling so that the main unit can be installed as shown
in the diagram. (The method for using the template and the gauge are shown.)
* Before using, check the dimensions of template and gauge, because they
change due to fluctuations of temperature and humidity.
* The dimensions of ceiling opening can be regulated within the range shown in
following diagram; so center the main unit against the opening of ceiling, ensuring
that the respective opposite sides on all sides of the clearance between them
becomes identical.
• Use M10 (3/8") suspension bolts.
* Suspension bolts are to be procured at the field.
• Install securely, ensuring that there is no clearance between the ceiling panel &
grille, and between the main unit & grille.
A Outer side of main unit
B Bolt pitch
C Ceiling opening
D Outer side of Grille
E Grille
F Ceiling
* Leave the maintenance space at the electric component box end.
*1 When installing in an existing ceiling unit location or applying additional heat insulation,
ensure a minimum space of 25 mm.
Accessory name
G Min. 500 mm (Entire periphery)
If setting the maintenance space for G, be
sure to leave is a minimum of 700 mm.
H Maintenance space
I Fresh air intake
J Angle
K Electric component box
en
Q'ty
1
4
4
1
1
6
2
2
1
1
3