G
B
THE INDICATORS OUTPUT OTHERWISE THE GATE FUNCTIONING COULD BE COMPROMISED OR THE
CONTROL BOARD COULD BE DAMAGED.
TECHNICAL SPECIFICATIONS
Humidity
Power supply voltage
Frequency
Interruptions in electricity supply
Maximum load of motor outputs
Maximum load of blinker output with resistive load
Maximum control board absorption (without accessories) 33 mA
Current available for photocells and accessories
IP protection grade
Control board weight
Dimensions
TECHNICAL RADIO SPECIFICATIONS (model CRX)
Reception frequency
Impedance
Sensitivity
Time of excitation
Time of discharge
Memory available
Maximum load of radio receiver output
- All inputs shall be used as clean contacts without earthing, because the power supply is
generated in the card and is structured in such a way to guarantee the respect of double and
reinforced insulation to the elements under voltage
- All inputs are managed by a programmed circuit that carries out a self-control every time
the gate is operated.
TROUBLESHOOTING
After having carried out all connections, by carefully following the layout and having positioned
the gate in intermediate position, check the correct ignition of LEDS DL3, DL4, DL7, DL8.
In case of no ignition of the LEDS, always with gate in intermediate position, check the following
and replace any faulty components.
DL3
switched OFF
Faulty opening limit switch
DL4
switched OFF
Faulty closing limit switch
DL7
switched OFF
Faulty photocells
DL8
switched OFF
Faulty safety edge (In case the edge is not connected, carry out
jumper between COM and EDGE)
During functioning with personnel present, with DIP 1 to ON, check that during opening the
green DL6 LED switches on and that during closing the red DL5 LED switches on.
If not, invert clamps V and W on the motor terminal board.
After having carried out the various connections and having supplied
voltage, all the LEDS are switched OFF.
The motor opens and closes, but it has no strength and moves slowly.
The gate opens but does not close after the time set.
The gate does not open or close by activating the various K and RADIO
buttons.
By activating the K button the gate does not move.
The slowing phase is not performed.
< 95% without condensation
230V~ ±10% (120V/60 Hz upon
request)
50/60 Hz
20 ms
1 CV
40 W
0,4 A±15% 24 Vdc
IP 54
0,55 kg
130 x 50 x 115 mm
433,92 MHz
52 Ω
>2,24 µV
300 ms
300 ms
60 codes (30 for complete opening
and 30 for pedestrian opening)
200 mA 24 Vdc
FAULT
Check the integrity of fuses F1 and F2.
In case of interrupted fuse use only of adequate value F2 = 5A F1 = 100mA.
Check trimmers TORQUE and LOW-SPEED adjustment.
Ensure to have set DIP 3 to ON. Button K BUTTON always inserted in automatic functioning mode (DIP 6 OFF). Replace
button or switch of the selector switch.
Failed edge self-test => check the connections between electronic board and edge feeder.
Attention: if not using a feeder for edges, DIP 10 must be at OFF position.
Faulty safety edge contact. Faulty photocells contact with DIP 4 to OFF.
Fix or replace the relative contact.
Impulse K always inserted. Check and replace any buttons or micro-switches of the selector switch.
Ensure that DIP 8 is OFF (slowing enabled).
Learn the times through procedure from DIP 2.
Check trimmer LOW-SPEED adjustment.
32