Junction box GHG 79101
Fig. 1
8
Explosion protected junction boxes,
type GHG 791 01 and GHG 791 02
2
Principls
Caution
This symbol warns of a possible failure.
Failure to observe this caution may result in
the total failure of the device or the system
or plant to which it is connected.
X
Special conditions
ATEX - IEC
This symbol shows Highlights for safe use in
accordance to EU-Type-Examination Certificate/
IEC Ex-Certificate of Conformity.

2.1 Safety instructions

a
The operations must be carried
out by electrical suitably trained in
hazardous area with knowledge of
increased safety explosion protection and
IEC/EN 60079-14.
T he junction boxes are not suitable for Zone
0 and Zone 20 hazardous areas. T he
temperature class and explosion group
marked on the junction boxes shall be
observed.
The requirements of the IEC/EN 60079-31
regarding excessive dust deposits and
temperature to be considered from the user.
They shall be used for their intended
purpose and in perfect and clean condition.
Prior to taking the junction boxes into
operation, they shall be checked in accord-
ance with the instruction as per section 6.
Observe the national safety rules and
regulations for prevention of accidents as
well as the safety instructions included in
these operating instructions and set in
italics the same as this text!
3

Conformity with standards

The apparatus is conform to the standards
specified in the EU-Declaration of conformity,
enclosed separately.
References to standards and directives in these
operating instructions always relate to the latest
version. Other additions (e.g. details relating to
the year) shall be observed.
4

Field of application

The junction boxes GHG 791 01 and GHG 791
02 are suitable for use in Zones 1 and 2 as well
as in Zones 21 and 22 hazardous areas acc. to
IEC/EN 60 079-10-1 and IEC/EN 60 079-10-2!
The enclosure materials employed, including
the exterior metal parts, are made of
high-quality materials which ensure a corrosion
protection and resistance to chemical
substances corresponding to the requirements
in a "normal industrial atmosphere":
– impact resistant polyamide
– special steel AISI 316 L
For use in an extremely aggressive atmosphere,
please contact your EATON / COOPER
CROUSE-HINDS agent for additional informa-
tion on the chemical stability of the plastics
used.
5
Use/Properties
The junction boxes are intended for the
distribution of electrical energy (e.g. light
circuits, heater circuits, control circuits etc.) in
hazardous areas up to max. 28 A (see technical
data). The temperature class, explosion group
and permissible ambient temperature, see
technical data.
If the conductor cross-section in the junction
box is reduced, the maximum capacity of
the conductor with the smallest cross-sec-
tion and the rated current of the junction
box must be taken into account.
The data as per point 3 and 4 shall be taken
into account with the use.
Applications other than described are not
permitted without EATON / COOPER
CROUSE-HINDS's prior written consent.
For the operation, the instructions stated in
section 7 of the operating instructions shall
be observed.
The user alone is responsible for the
appropriate use of this junction box in
consideration of the basic conditions
existing at the plant (see technical data).
6

Installation

For the mounting and operation, the respective
national regulations as well as the general rules
of engineering shall be observed
(IEC/EN 60079-14).