tEChNICAL ChARACtERIstICs (Drawing J)
Reference
Voltage
ECO
Power DC
MAX
Mode
NIGHT
ECO
Power AC
Mode
MAX
NIGHT
Cooling performance Delta T*
(+/-1°C)
MAX mode at 32°C ambient
Cooling performance Delta T*
(+/-1°C)
NIGHT mode at 25°C ambient
Battery control
Insulation
Refrigerating system:
Peltier system
Dimensions (cm)
(Drawing J)
A
B
C
GB
D
E
F
* The temperature difference, called Delta T and symbolized by "∆T", represents the decrease in temperature between outside and inside
of the cooler.
PowerBox
PLUS 24L 12V/230V
®
2000030252
2000030256
12V
7 W
48 W
45 W
8.8 W
57 W
53 W
20.5 °C (+/-1.5 °C)
15 °C (+/-1 °C)
PU
32.8
24.3
31
32.3
40.8
42.3
PowerBox
PLUs 28L 12V/230V
®
2000030253
2000030257
12V
7 W
48 W
45 W
8.8 W
57 W
53 W
20 °C (+/-1 °C)
15 °C (+/-1 °C)
PU
32.8
24.3
34.8
32.3
40.8
46.9
10
PowerBox
PLUS 36L 12V/230V
®
2000030254
2000030258
12V
8 W
54 W
52 W
8.5 W
75 W
67 W
18 °C (+/-1 °C)
16 °C (+/-1 °C)
PU
46.7
27.5
29
34.8
55.9
40.4