6.7. MANUAL SENDING OF PROCESS DATA
To send the process data manually, the upload command must be triggered as de-
scribed in the operating modes� To do this, you must turn the star grip all the way to
the left (figure E), and press and hold the main switch (figure M; no. 1) for 15 seconds.
6.8. PERFORMING A SOFTWARE UPDATE
After you have registered your device, Captium checks the software version in-
stalled on your rescue device, battery or charger, and indicates if there is a newer
version� These updates should be carried out promptly� The device needs to be
switched to "Firmware update" mode� To do so, turn the star grip all the way to the
left (figure E) and press and hold the main switch (figure M; no. 1) for 7 seconds.
6.9. PERFORMING THE SELF-TEST
The rescue device can test itself in test mode and transmit the results to Captium
for display. To do so, you must turn the star grip all the way to the right (figure H)
and press and hold the main switch (figure M; no. 1) for 7 seconds. The device is
now in test mode� After that, you will be guided through the process by the illumi-
nated direction indicators. The device must first be closed completely and then
opened all the way again without load and closed all the way again� When the
procedure has ended, the power supply interrupted or the device is not activated
for 20 seconds, it automatically switches back to normal operation� The results of
the self-test can be called up in Captium�
6.10. WIFI CONNECTION QUALITY INDICATOR
A minimum WiFi signal strength is required for reliable data transmission� If WiFi is
activated on the device, the signal strength is indicated by the battery status LEDs�
The signal strength indicated by the LEDs is shown in the illustration below�
From the user's point of view, this means that two or more LEDs indicate that the
signal strength is sufficient for a reliable data transmission.
6.11. WLAN TECHNICAL DATA
Transmission standard:
Frequency range:
Maximum transmission power: 20 dBm
7. MAINTENANCE AND CARE
7.1. GENERAL MAINTENANCE
A visual check is to be carried out after each use� After every use, the lubrication of
the moving parts and bolts must be checked and topped off with a suitable grease,
if necessary� The torque of the central bolt on cutting and combination tools must
also be checked. To do so, check the specifications in the spare parts lists.
RSSI > -57 dBm
-57 dBm >= RSSI > -69 dBm
-69 dBm >= RSSI > -80 dBm
RSSI < -80 dBm
IEEE 802�11 b/g/n
2412 - 2484 MHz
en