6.3.1.
SWITCHING ON ROUTER MODE ON THE DEVICE
To do this, move the star grip all the way to the right (figure H) and simultaneously
press the main switch (figure M; no. 1) for 15 seconds. The rescue device now
establishes a WLAN network�
6.3.2.
SEARCHING FOR A RESCUE DEVICE WITH WLAN CAPABILITY
en
The network established by the rescue device can be found by a WLAN-capable
device (mobile phone, tablet or laptop)� Search in the available networks for the
"Jaws of Life" network and enter the password "12345678"�
6.3.3.
AFTER SUCCESSFUL CONNECTION
If there is a WLAN connection, scan the QR code (figure O) on the rescue device
or enter the IP address http://192.168.66.1/ into the Internet browser of your termi-
nal device. Now the input screen for the network connection opens (figure P).
6.3.4.
INPUTTING THE NETWORK INTO THE PAIRING APP
Now choose your network with which the rescue device is to communicate� To do so,
the network name (figure P; no. 1) and password (figure P; no. 2) is required. The pass-
word (figure P; no. 3) must be entered twice. Between one and ten networks can be
es
stored, via which the rescue device should exchange data with Captium� After you have
entered the first network, confirm with the Next button (figure P; no. 4). After that, anoth-
er network can be entered� After all networks have been entered, end the process by
pressing the Finish button (figure P; no. 5). A confirmation screen appears, the WLAN
symbol (figure M; no. 8) flashes and the workspace lighting is switched back on. Make
sure that the following ports have been enabled in the network to be connected�
Port
123
8883
443
fr
6.4. REGISTERING THE DEVICE IN CAPTIUM
The Captium instructions explain how to register your rescue device in Captium�
6.5. AUTOMATIC SENDING OF PROCESS DATA
While you are working with the rescue device, the process data is collected in the
internal memory� If there is data in this memory, a battery is plugged in, and the device is
switched off, the rescue device will then search every 20 minutes for the networks it rec-
ognizes� If no connection with a network is possible, it will search again after 20 minutes�
After three attempts, the rescue device will wait 45 minutes before carrying out a final
search, after which it will interrupt the search and leave the data in the internal memory�
If the rescue device can establish a connection, it sends the data to Captium and deletes
pt
the entry in the internal memory as soon as Captium has received the data� If the inter-
nal memory does not contain any data, the rescue device doesn't search for a network�
6.6. MONITORING THE BATTERY'S REMAINING CAPACITY
The devices monitor the battery capacity of the inserted battery� The device switch-
es itself on every seven days to monitor the capacity� If the remaining capacity falls
below 35%, the rescue device sends Captium an alarm if WLAN is available�
12
Protocol
Purpose
UDP & TCP
Used to synchronize the time on the rescue device over
the Internet via NTP�
UDP & TCP
IoT Hub MQTT connection�
UDP & TCP
Device Provisioning Service HTTPS connection�